Operation
4.4.2
Setting the response values for undervoltage and overvoltage
How to proceed
1.
Open menu "AL".
2.
Select parameter "U<" for undervoltage or
parameter "U>" for overvoltage.
3.
Set value and confirm with Enter.
4.4.3
Response values overview
Display
Activation
FAC
R1 <
on
R2 <
on
U <
off
U >
off
FAC Factory settings
Cs
Customer settings
22
isoES425_D00214_01_M_XXEN/10.2023
Cs
Range
not
R2 ... 990
adjustable
not
1 ... R1
adjustable
10 ... U>
U< ... 500
Setting value
FAC
69
23
30
500
Description
Cs
Prewarning value R
k
Hys. = 25 % / min. 1 k
Alarm value R
an2
k
Hys. = 25 % / min. 1 k
Alarm value undervoltage RMS
V
Hys. = 5 % / min. 5 V
Alarm value overvoltage RMS
V
Hys. = 5 % / min. 5 V
an1
Need help?