Bender ISOMETER isoCHA425HV Manual (46 pages)
Insulation monitoring device with coupling device for unearthed DC systems (IT systems) DC 0 V to 1000 V
Brand:
Bender
| Category:
Measuring Instruments
| Size: 3 MB
Table of Contents
Table of Contents
3
1 General Instructions
5
How to Use this Manual
5
Indication of Important Instructions and Information
5
Signs and Symbols
5
Training Courses and Seminars
5
Delivery Conditions
5
Inspection, Transport and Storage
6
Warranty and Liability
6
Disposal of Bender Devices
6
Safety
6
2 Function
7
Intended Use
7
Device Features
7
Functional Description
8
And C in "Chd" Mode (Chademo)
8
And C in "DC" Mode (CCS)
8
Fault Location R
9
System Leakage Capacitance C E
9
System Voltages U L1E and U L2E
9
Functional Tests of Contactors in the Charging Station and the Vehicle
9
Monitoring of the Insulation Resistance
9
Undervoltage/Overvoltage Monitoring
9
Stop Mode
10
Self Test Functions (Device Errors)
10
Cyclic Background Test
10
Continuous PE Connection Monitoring
10
User-Controlled Test Functions
10
Internal and External Test Button
10
Timer for Test Functions
10
Device Test at Device Start
10
System Connection Test L1/+ and L2
11
Alarm Assignment of the Alarm Relays K1/K2
12
Measuring and Response Times
12
Password Protection (On, OFF)
13
Factory Setting FAC
13
External, Combined Test or Reset Button T/R
13
Fault Memory
13
History Memory His
13
Interface/Protocols
13
3 Dimensions and Mounting
15
Dimensions
15
Mounting
15
Wiring Diagram
16
Commissioning
17
4 Operation of the Device
19
Displays and Buttons
19
Menu Overview
20
AL" Menu
21
Setting Response Value
21
Out" Menu
21
Relay Mode Configuration
21
Relay Alarm Assignment "R1" and "R2" and LED Assignment
21
Fault Memory Configuration
22
Interface Configuration
22
T" Menu
23
Time Configuration
23
Set" Menu
23
Function Configuration
23
Measured Value Display and History Memory
24
5 Data Access Using the BMS Protocol
25
6 Data Access Using the Modbus RTU Protocol
27
Reading out Modbus Registers from the ISOMETER
27
Command of the Master to the ISOMETER
27
Response of the ISOMETER® to the Master
27
Writing to Modbus Registers (Parameter Setting)
27
The Master Sends a Command to the ISOMETER
27
Response of the ISOMETER® to the Master
28
Exception Code
28
Structure of the Exception Code
28
7 Modbus Register Assignment of the ISOMETER
29
Device-Specific Data Type of the ISOMETER
31
Device Name
31
Measured Values
32
Float = Floating Point Value of the Channels
32
AT&T = Alarm Type and Test Type (Internal/External)
33
R&U = Range and Unit
34
Alarm Assignment of the Relays
35
Channel Descriptions
35
8 Isodata Data String
37
9 Technical Data
39
Standards, Approvals and Certifications
43
Ordering Information
43
Declaration of Conformity
44
Advertisement
Bender ISOMETER isoCHA425HV Manual (52 pages)
Brand:
Bender
| Category:
Measuring Instruments
| Size: 5 MB
Table of Contents
Table of Contents
3
General Information
6
How to Use the Manual
6
Indication of Important Instructions and Information
6
Signs and Symbols
6
Service and Support
6
Training Courses and Seminars
7
Delivery Conditions
7
Inspection, Transport and Storage
7
Warranty and Liability
7
Disposal of Bender Devices
8
Safety
8
Function
9
Intended Use
9
Device Features
9
Functional Description
10
R F and C E in "Chd" and "CHA" Mode (Chademo)
11
R F and C Mode in "DC" Modmode (CCS)
11
Fault Location R
11
System Leakage Capacitance C
11
System Voltages U L1E and U L2E
11
Functional Tests of Contactors in the Charging Station and the Vehicle
12
Monitoring the Insulation Resistance
12
Undervoltage/Overvoltage Monitoring
12
Stop Mode
12
Self Test Functions (Device Errors)
12
2.3.11 Error Codes
14
Alarm Assignment of the Alarm Relays K1/K2
14
2.3.13 Fault Memory
15
2.3.14 Digital Interface
15
2.3.15 Measuring and Response Times
16
Password Protection (On, OFF)
16
External Test/Reset Button (T/R)
16
2.3.18 History Memory His
17
Installation, Connection and Commissioning
18
Dimensions
18
Installation
18
Connection
18
Commissioning
21
Operation
22
Operating and Display Elements
22
Menu Overview
24
Displaying Measured Values
25
Setting the Response Values (AL)
26
Response Values Overview
26
Setting the Response Values for Monitoring the Insulation Resistance
26
Setting the Response Values for Undervoltage and Overvoltage
26
Configuring Fault Memory, Alarm Relays, and Interfaces (Out)
26
Configuring the Relays
27
Assigning the Alarm Messages to the Relays
27
Activating or Deactivating Fault Memory
28
Configuring Interface
28
Setting Delay Times and Self Test Cycles (T)
28
Setting Device Control Parameters (Set)
29
Reset to Factory Settings
29
Showing and Deleting the History Memory
29
Querying Software Version (Inf)
30
Data Access Via RS-485 Interface
31
Data Access Using the BMS Protocol
31
Data Access Using the Modbus RTU Protocol
31
Reading out the Modbus Register from the ISOMETER
31
Writing the Modbus Register (Parameter Setting)
32
Exception Code
33
Modbus Register Assignment
34
Modbus Measured Value Registers
34
Modbus Parameter Register
37
Isodata Data String
41
Technical Data
42
Technical Data Isocha425Hv
42
Technical Data AGH420-1 and AGH421-1
47
Connection (for ISOMETER® and AGH) (for ISOMETER® and ZE420)
48
Bender ISOMETER isoCHA425HV Quick Start Manual (13 pages)
Insulation monitoring device with coupling device for unearthed DC systems DC 0 V up to 1000 V
Brand:
Bender
| Category:
Measuring Instruments
| Size: 1 MB
Table of Contents
Bestimmungsgemäße Verwendung
2
Intended Use
2
Montage
4
Wiring Diagram
5
Control Panel
6
Display Elements
6
Menü-Übersicht
7
Menu Overview
7
Error Codes
9
Technical Data
10
EU-Konformitätserklärung
12
EU Declaration of Conformity
12
Advertisement
Bender ISOMETER isoCHA425HV User Manual (13 pages)
Insulation monitoring device with coupling device
Brand:
Bender
| Category:
Measuring Instruments
| Size: 1 MB
Table of Contents
Montage
4
Wiring Diagram
4
Wiring Diagram Legend
5
Menü-Übersicht
6
Menu Overview
6
Display Elements
7
Technische Daten
8
Technical Data
8
Eu-Konformitätserklärung
11
Bender ISOMETER isoCHA425HV Quick Start Manual (13 pages)
Insulation monitoring device with coupling device for unearthed DC systems DC 0V up to 1000V
Brand:
Bender
| Category:
Measuring Instruments
| Size: 1 MB
Table of Contents
Ordering Data
2
Montage
4
Wiring Diagram
4
Wiring Diagram Legend
5
Menü-Übersicht
6
Menu Overview
6
Display Elements
7
EU-Konformitätserklärung
11
Advertisement
Related Products
Bender ISOMETER isoCHA425
Bender isoCHA425HV-D4-4+AGH420-1
Bender isoCHA425HV-D4-4+AGH421-1
Bender isoCHA425-D4-4
Bender isoCHA425HV-D4-4
Bender ISOMETER isoUG425
Bender ISOMETER isoEV425
Bender ISOMETER isoPV1685DP-425
Bender ISOMETER iso685-S
Bender ISOMETER iso685W-D-B
Bender Categories
Measuring Instruments
Monitor
Control Unit
Control Panel
Relays
More Bender Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL