Sign In
Upload
Manuals
Brands
Bender Manuals
Measuring Instruments
ISOMETER isoUG425
Bender ISOMETER isoUG425 Manuals
Manuals and User Guides for Bender ISOMETER isoUG425. We have
5
Bender ISOMETER isoUG425 manuals available for free PDF download: Manual, Quick Start Manual, Operating Manual
Bender ISOMETER isoUG425 Manual (44 pages)
Insulation monitoring device for earth fault detection in unearthed DC systems up to 120 V Software version: D0476 V2.xx
Brand:
Bender
| Category:
Measuring Instruments
| Size: 2 MB
Table of Contents
Table of Contents
3
General Information
5
How to Use the Manual
5
Indication of Important Instructions and Information
5
Signs and Symbols
5
Service and Support
5
Training Courses and Seminars
6
Delivery Conditions
6
Inspection, Transport and Storage
6
Warranty and Liability
6
Disposal of Bender Devices
7
Safety
7
Function
8
Intended Use
8
Device Features
8
Function Description
8
Monitoring the Insulation Resistance
9
Undervoltage/Overvoltage Monitoring
9
Self Test/Error Codes
9
Malfunction
10
Alarm Assignment of the Alarm Relays K1/K2
11
Measuring and Response Times
11
Password Protection (On, OFF)
12
Maximum Permissible System Leakage Capacitance
12
External Test/Reset Button (T/R)
12
2.3.10 Fault Memory
12
2.3.11 History Memory His
13
2.3.12 Digital Interface
13
Installation, Connection and Commissioning
14
Dimensions
14
Installation
14
Connection
15
Commissioning
16
Operation
18
Operating and Display Elements
18
Menu Overview
20
Displaying Measured Values
21
Setting the Response Values (AL)
21
Setting the Response Values for Monitoring the Insulation Resistance
21
Setting the Response Values for Undervoltage and Overvoltage
22
Response Values Overview
22
Configuring Fault Memory, Alarm Relays, and Interfaces (Out)
22
Configuring the Relays
22
Assigning the Alarm Messages to the Relays
22
Activating or Deactivating Fault Memory
23
Configuring Interface
24
Setting Delay Times and Self Test Cycles (T)
24
Setting Device Control Parameters (Set)
25
Reset to Factory Settings
25
Showing and Deleting the History Memory
25
Querying Software Version (Inf)
25
Data Access Via RS-485 Interface
26
Data Access Using the BMS Protocol
26
Data Access Using the Modbus RTU Protocol
26
Reading out the Modbus Register from the ISOMETER
26
Writing the Modbus Register (Parameter Setting)
27
Exception Code
28
Modbus Register Assignment
29
Modbus Measured Value Registers
29
Modbus Parameter Register
32
Isodata Data String
36
Technical Data
37
Technical Data Isoug425
37
Connection
40
Standards and Certifications
41
Ordering Data
41
Change Log
42
Advertisement
Bender ISOMETER isoUG425 Operating Manual (32 pages)
Insulation monitoring device for earth fault detection in unearthed DC systems IT systems up to 120 V, Software version: D0476 V2.xx
Brand:
Bender
| Category:
Measuring Instruments
| Size: 1 MB
Table of Contents
Table of Contents
3
1 Important Information
5
How to Use this Manual
5
Technical Support: Service and Support
5
First Level Support
5
Repair Service
5
Field Service
6
Training Courses
6
Delivery Conditions
6
Inspection, Transport and Storage
6
Warranty and Liability
6
Disposal
6
2 Safety Instructions
7
General Safety Instructions
7
Work Activities on Electrical Installations
7
Intended Use
7
3 Function
8
Device Features
8
Function Description
8
Monitoring the Insulation Resistance
8
Undervoltage/Overvoltage Monitoring
8
Self Test/Error Codes
8
Malfunction
9
Signalling Assignment of the Alarm Relays K1/K2
9
Measuring and Response Times
9
Password Protection (On, OFF)
10
Maximum Permissible Leakage Capacitance
10
Factory Setting FAC
10
External, Combined Test or Reset Button T/R
10
Fault Memory
10
History Memory His
10
Interface/Protocols
11
4 Installation, Connection and Commissioning
12
Mounting
12
Wiring Diagram
12
Commissioning
14
5 Operation of the Device
15
Display Elements in Use
15
Menu Structure
16
AL" Menu
16
Response Value Setting
16
Out" Menu
17
Configuration of the Relay Operating Mode
17
Relay Alarm Assignment "R1" and "R2" and LED Assignment
17
Fault Memory Configuration
17
Interface Configuration
17
T" Menu
18
Time Configuration
18
Set" Menu
18
Function Configuration
18
Measured Value Display and History Memory
18
6 Data Access Using the BMS Protocol
19
7 Data Access Using the Modbus RTU Protocol
20
Reading out the Modbus Register from the ISOMETER
20
Command of the Master to the ISOMETER
20
The ISOMETER® Answers the Master
20
Writing the Modbus Register (Parameter Setting)
20
Exception Code
21
Structure of the Exception Code
21
8 Modbus Register Assignment of the ISOMETER
22
Device-Specific Data Type of the ISOMETER
24
Device Name
24
Measured Values
24
Float = Floating Point Value of the Channels
24
AT&T = Alarm Type and Test Type (Internal/External)
24
R&U = Range and Unit
25
Alarm Assignment of the Relays
25
Channel Descriptions
26
9 Isodata Data String
27
10 Technical Data
28
Tabular Representation
28
Standards, Approvals and Certifications
29
Ordering Information
29
Index
30
Bender ISOMETER isoUG425 Quick Start Manual (41 pages)
Insulation monitoring device for unearthed, DC systems (IT systems) up to 120 V
Brand:
Bender
| Category:
Measuring Instruments
| Size: 1 MB
Table of Contents
Sicherheitshinweise Allgemein
2
Montage und Anschluss
3
Menü-Übersicht
8
Technische Daten
15
Intended Use
19
Safety Information
20
Functional Description
20
Installation and Connection
21
Din Rail Mounting
21
Screw Mounting
21
Wiring Diagram
22
Wiring Diagram Legend
23
Error Codes
24
Menu Overview
26
Response Settings
27
Display Activation
27
Fault Memory Configuration
29
Interface Configuration
30
Configuring Time Settings
30
Technical Data
33
Standards, Approvals and Certifications
37
Advertisement
Bender ISOMETER isoUG425 Operating Manual (37 pages)
Insulation monitoring device for unearthed, DC systems IT systems up to 120 V, Software version: D476 V2.xx
Brand:
Bender
| Category:
Measuring Instruments
| Size: 1 MB
Table of Contents
Sicherheitshinweise Allgemein
2
Montage und Anschluss
3
Menü-Übersicht
7
Technische Daten
14
Intended Use
19
Safety Information
20
Functional Description
20
Installation and Connection
21
Din Rail Mounting
21
Screw Mounting
21
Wiring Diagram Legend
23
Error Codes
23
Menu Overview
25
Response Settings
26
Fault Memory Configuration
28
Interface Configuration
29
Configuring Time Settings
29
Technical Data
32
Time Response
33
Switching Elements
33
Ordering Information
35
Bender ISOMETER isoUG425 Quick Start Manual (9 pages)
Insulation monitoring device for earth fault detection in unearthed DC systems up to 120 V
Brand:
Bender
| Category:
Measuring Instruments
| Size: 0 MB
Table of Contents
Montage
3
Wiring Diagram
4
Control Panel
5
Display Elements
5
Menü-Übersicht
6
Menu Overview
6
Technische Daten
7
Technical Data
7
EU-Konformitätserklärung
8
EU Declaration of Conformity
8
Advertisement
Related Products
Bender ISOMETER iso685-D-P
Bender ISOMETER isoNAV685-D-B
Bender ISOMETER isoPV with AGH-PV
Bender ISOMETER iso1685DP-425
Bender ISOMETER isoHV1685D-425
Bender ISOMETER isoLR1685DP-325
Bender ISOMETER isoEV425
Bender ISOMETER isoCHA425
Bender ISOMETER iso165C
Bender ISOMETER iso165C-1
Bender Categories
Measuring Instruments
Monitor
Control Unit
Control Panel
Relays
More Bender Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL