Design and function
Notes on the installation of welding current leads
5.6
Notes on the installation of welding current leads
Incorrectly installed welding current leads can cause faults in the arc (flickering).
Lay the workpiece lead and hose package of power sources without HF igniter
(MIG/MAG) for as long and as close as possible in parallel.
Lay the workpiece lead and hose package of power sources with HF igniter (TIG) for as
long as possible in parallel with a distance of 20 cm to avoid HF sparkover.
Always keep a distance of at least 20 cm to leads of other power sources to avoid
interferences.
38
NOTE
Figure 5-3
099-003133-SCO01
07.04.2014
Need help?
Do you have a question about the Tetrix 352 AC/DC SYNERGIC PL. AW GR and is the answer not in the manual?
Questions and answers