Design and function
Menus and sub-menus on the machine control
Display
84
Setting/selection
Welding current polarity switching
on = polarity switching at the RT PWS 1 19POL remote control (ex works)
off = polarity switching at the welding machine control
spotMatic
Variation of operation mode spotArc, ignition with workpiece contact
on = on
off = off (factory setting)
Short spot time
Setting of 5–-999 ms (1-ms steps)
Setting process activation
on = Separate process activation:
The welding process has to be reactivated for every arc ignition by pressing the torch
trigger.
off = Permanent process activation:
The welding process is activated by pressing the torch trigger once. The following arc
ignitions are initiated by shortly touching the tungsten electrode against the
workpiece.
Torch cooling mode
AUt = automatic operation (ex works)
on = permanently switched on
off = permanently switched off
Water block pre-flow time
Setting 1–60 min. (ex works 5)
Expert menu
AC mean value controller
on = on (factory setting)
off = off
Switching option for welding current potential (dc+) with TIG DC
off = Select option for TIG DC+ is blocked (factory setting). Serves to protect the
tungsten electrode from being destroyed.
on = Polarity can be selected freely
Reconditioning pulse (spherical cap stability)
on = function on (factory setting)
off = function off
activArc voltage measuring
on = function on (factory setting)
off = function off
Error output to automated welding interface, contact SYN_A
off
AC synchronisation or hot wire (factory setting)
FSn
Error signal, negative logic
FSP
Error signal, positive logic
AvC
AVC (Arc voltage control) connection
Automation menu
Fast take-over of control voltage (automation)
on = function on
off = function off (factory setting)
Orbital welding
off = off (ex works)
on = on
Orbital welding
Correction value for orbital current