Display
099-003133-SCO01
07.04.2014
Setting/selection
Exit the menu
Exit
Torch configuration menu
Set welding torch functions
Torch mode (factory setting 1)
Up-/Down speed
Increase value
= rapid current change (factory setting 10)
Reduce value
= slow current change
Setting the first increment
Setting: 1 to 20 (factory setting 1)
Get JOB number
Set maximum selectable jobs (setting: 1 to 128, factory setting 10).
Additional parameter after activating the BLOCK JOB function.
Start JOB
Set first JOB to get (setting: 129 to 256, factory setting 129).
Machine configuration
Settings for machine functions and parameter display
Operating principle
•
on = synergic parameter setting (factory setting)
•
off = conventional parameter setting
Welding current display (ignition, secondary, end and hotstart currents)
•
Pro = welding current display as a percentage of the main current (factory setting)
•
Abs = absolute welding current display
Non-latched operation (C version)
•
on = on
•
off = off (factory setting)
Setting for the primary setpoint value display
Defines the priority display for setpoint values:
•
bld = panel thickness
•
vol = welding voltage (factory setting)
RINT X12, JOB control for automation solutions
•
on = on
•
off = off (factory setting)
Power display switching (MMA)
•
on = actual value display
•
off = setpoint value display (factory setting)
Pulses in the upslope and downslope phases
The function can be switched on or off
additional wire welding, operating mode
•
I>0 = filler wire mode for automated applications,
wire is conveyed when current flows
•
2t (factory setting) to 4t = operating mode non-latched to latched
Machine configuration (part two)
Settings for machine functions and parameter display
Ramp function Remote control RTF 1
The ramp function can be switched on and off
Kalottenbildung mit Remote control
•
on = on (ex works)
•
off = off
Tungsten balling (old variant)
•
on = on
•
off = off (ex works)
Design and function
Menus and sub-menus on the machine control
83
Need help?
Do you have a question about the Tetrix 352 AC/DC SYNERGIC PL. AW GR and is the answer not in the manual?
Questions and answers