To Set The Com/Id Tone/Code Modulating Frequency; To Set The Com/Id Tone Am Depth; To Set Or Return The Com/Id Parameters To A Default State - Keysight N5166B CXG User Manual

Signal generator
Table of Contents

Advertisement

Avionics VOR/ILS (Option N5180302B)
Using COM/ID Softkeys
To find a valid COM/ID code (airport communication identification code) for a particular area, refer
to the following websites:
Airline Coding Directory (http://www.iata.org)
AirNav (http://www.airnav.com)

To set the COM/ID tone/code modulating frequency

1. Press Aux Fctn > Avionics > VOR
2. Press COM/ID
3. Press Frequency
(Default value is 1.02000 kHz.)
4. Select a value in Hz | kHz | MHz | GHz from 0 Hz to 20 kHz.
Enter a value in Hz to set the frequency of the COM/ID tone modulating frequency.

To set the COM/ID tone AM depth

1. Press Aux Fctn > Avionics > VOR
2. Press COM/ID
3. Press Depth
(Default value is 10%.)
4. Select a value from 0 to 49.9% and press Enter.
Enter a value in percentage to set the COM/ID tone AM depth.

To set or return the COM/ID parameters to a default state

1. Press Aux Fctn > Avionics > VOR
2. Press COM/ID
3. Press More 1 of 2
4. Press Recall Default Settings
146