Keysight N5166B CXG User Manual page 292

Signal generator
Table of Contents

Advertisement

Basic Digital Operation (Option 653/655/656/657)
Understanding Option 012 (LO In/Out for Phase Coherency) with Multiple Baseband Generator
Synchronization
— The phase coherency feature only applies to the Dual ARB modulation mode.
— All cables from the splitter output to the instrument inputs should be of equal lengths.
Table 9-5
Option 012 (LO In/Out for Phase Coherency) Equipment
MIMO Configuration
2x2
3x3
4x4
All
a. On all of the MIMO configurations, the same length of SMA flexible cables are connected
from the splitter output to the inputs on the primary and secondary instruments. Refer to
Figure 9-30 on page 293
292
Cable Length
a
Part
n/a
As required
11636A
n/a
n/a
As required
PS3–20–
n/a
451/12S
n/a
As required
PS4–16–
n/a
452/10S
10502A
22.86 cm (9 inches)
and to
Figure 9-31 on page
Keysight CXG, EXG, and MXG X-Series Signal Generators User's Guide
Notes
SMA flexible cables are connected from
the power splitter outputs to the LO
inputs on the rear panel of both the
primary and secondary MXG/EXGs.
Refer to
Figure 9-30 on page 293
Power Divider, DC to 18 GHz. Refer to
www.keysight.com.
SMA flexible cables are connected from
the power splitter outputs to the LO
inputs on the rear panel of the
secondary MXG/EXGs. Refer to
.
9-31 on page 294
3–Way Pulser Microwave Corp., 3–Way
Wilkinson Dividers
The SMA flexible cables are connected
to the power splitter output to the LO
inputs on the rear panel of the
secondary MXG/EXGs. Refer to
.
9-31 on page 294
4–Way Pulser Microwave Corp., 4–Way
Wilkinson Dividers
Refer to
Figure 9-30 on page 293
. See also
Figure 9-31 on page 294
"Multiple Baseband Generator
Synchronization" on page 285
294.
.
Figure
Figure
and
.

Advertisement

Table of Contents
loading

Table of Contents