5
Raise or reduce the value with the up or down buttons. The graph shows how the curve
slope changes.
6
Press the left button three times to exit the menu.
5 .4

Adjusting a specific part of the heat curve

To change a specified part of the heat curve:
1
Press either the right or left button once to open the INFORMATION main menu. The
cursor is in the OPERATION menu option.
2
Press the down button to move the cursor to the HEATCURVE menu option.
3
Open the menu by pressing the right button once. The cursor is at the CURVE value.
4
Select CURVE 5, CURVE 0 or CURVE -5 using the up or down buttons.
5
Open your selection by pressing the right button once.
6
Raise or reduce the value with the up or down buttons.
7
Press the left button three times to exit the menu.
5 .5

Setting MAX and MIN values

To change MIN or MAX:
1
Press either the right or left button once to open the INFORMATION main menu. The
cursor is in the OPERATION menu option.
2
Press the down button to move the cursor to the HEATCURVE menu option.
3
Open the menu by pressing the right button once. The cursor is at the CURVE value.
4
Press the down button to move the cursor to MIN.
5
Open your selection by pressing the right button once. The text row MIN is marked.
6
Raise or reduce the value with the up or down buttons.
7
Press the left button three times to exit the menu.
Repeat the procedure to change the MAX value, but select MAX instead of MIN at step 4.
5 .6

Setting HEATSTOP

To change HEATSTOP:
1
Press either the right or left button once to open the INFORMATION main menu. The
cursor is in the OPERATION menu option.
2
Press the down button to move the cursor to the HEATCURVE menu option.
3
Open the menu by pressing the right button once. The cursor is at the CURVE value.
4
Press the down button to move the cursor to HEATSTOP.
5
Open your selection by pressing the right button once. The text row HEATSTOP is
marked.
6
Raise or reduce the value with the up or down buttons.
7
Press the left button three times to exit the menu.
Danfoss – 26