Danfoss DHP-AL User Manual page 20

Table of Contents

Advertisement

3 .2 .3
Sub-menu HEATCURVE
In the HEATCURVE menu the settings that affect the
indoor temperature are made. For further information,
see the "About your heat pump" section.
Menu text
CURVE
MIN
MAX
CURVE 5
CURVE 0
CURVE - 5
HEATSTOP
REDUCTION
ROOM FACTOR
(Only displayed if
a Room sensor is
installed.)
Danfoss – 20
Description
The set value indicates the supply line
temperature of the water that is trans-
ported to the heating system at an out-
door temperature of 0°C.
Sets the lowest permitted supply
temperature.
Sets the highest permitted supply
temperature.
Used to adjust the heat curve at an
outdoor temperature of +5°C.
Used to adjust the heat curve at an
outdoor temperature of 0°C.
Used to adjust the heat curve at an
outdoor temperature of -5°C.
This function stops all production of
heat when the outdoor temperature is
equal to, or higher than, the set heat stop
value.
The temperature can be lowered using
an outside timer. The control computer
determines the drop.
Determines how large an impact the
room temperature is to have when calcu-
lating the supply temperature.
HEATCURVE
CURVE
MIN
MAX
CURVE 5
CURVE 0
CURVE -5
HEATSTOP
VUBMF102
Adjusted by:
By the customer, if
necessary.
By the customer, if
necessary.
By the customer, if
necessary.
By the customer, if
necessary.
By the customer, if
necessary.
By the customer, if
necessary.
By the customer, if
necessary.
By the customer, if
necessary.
Factory setting: 2
(interval: 1 - 5)
(1 = small, 5 = large)
40°c
22°c
70°c
0°c
0°c
0°c
17°c