3
Open the menu by pressing the right button once.
4
Note how many hours the following values have: HEAT PUMP, ADD.HEAT 1, ADD.HEAT 2
and ADD.HEAT 3.
5
Find the value for the average output that corresponds to your heat pump and heating
system in the table above, and multiply it by the number of HEAT PUMP hours. Note the
result.
6
Multiply the number of ADD.HEAT 1 hours by 3. Note the result.
7
Multiply the number of ADD.HEAT 2 hours by 6. Note the result.
8
Multiply the number of ADD.HEAT 3 hours by 6. Note the result.
9
Add up the multiplied values to obtain the total energy consumption.
5 .9

Manual defrost

If the outdoor unit requires defrosting you can run a defrosting procedure manually from the
control computer.
To defrost manually:
1
Press either the right or left button once to open the INFORMATION main menu. The cur-
sor is in the OPERATION menu option.
2
Press the down button to move the cursor to the DEFROST menu option.
3
Open the menu by pressing the right button once.
4
Press the down button to move the cursor to the MANUAL DEFROST menu option.
5
Press the right button once.
6
Press the up button once to start defrost.
7
Press the left button three times to exit the menu.