ALARM
The actual room temperature is
ROOM
not displayed. To calculate the
SENSOR
supply temperature's desired
value, use 20°C instead.
ERR PHASE
The compressor in the heat
SEQ.
pump is operating in the
wrong direction and this means
that only the auxiliary heater is
maintaining heating.
HIGH RETURN
The temperature of the water
that returns from the radiators
is too high and prevents the
heat pump from working.
9

Terms and abbreviations

Term
Evaporator
INTEGRAL
Compressor
Condenser
CURVE
Brine
Explanation
In the evaporator, energy from the heat source is absorbed by the
refrigerant passing through the evaporator. The refrigerant turns
into gas. (See the "About your heat pump" section for further infor-
mation).
INTEGRAL is the heating system's energy balance. Heat generation
is controlled by a calculated requirement. This value is determined
by comparing the actual supply temperature with its calculated
supply temperature. The difference between the temperatures is
multiplied by the time during which the difference is active. The
resulting value is referred to as the integral. The integral value is
automatically established when the heating system is in use. The
value of the integral can be viewed in the display under the sub-
menu TEMPERATURE.
The compressor raises the temperature and pressure of the refriger-
ant. (See the "About your heat pump" section for further informa-
tion).
In the condenser, the refrigerant supplies its heat energy to the
heat transfer fluid circuit. (See the "About your heat pump" section
for further information).
The CURVE value is set via the display. The set value indicates the
supply temperature of the water that is transported to the radiators
at an outdoor temperature of 0°C.
Is a water based mixture that transports energy from the heat
source to the heat pump. (See the "About your heat pump" section
for further information).
Cause
Electrical fault.
The phase
sequence changed
when changes
were made in the
electrical installa-
tion of the house.
Insufficiently
opened radiator/
floor loop thermo-
stats.
VUBMF102
Remedy
Contact your
installer.
Contact your
installer.
Ensure that all
thermostat valves
are fully open.