3 .2 .7
Sub-menu DEFROST
In the "DEFROST" menu it is possible to view miscel-
laneous information about the defrost and also pos-
sible to make adjustments.
Menu text
DEFROSTS
BETW. 2 DEFR
TIME SINCE
DEFROST
FAN H OFF AT
DEFROST CURVE
MANUEL DEFR
Description
Total number of defrosts carried out since
installation, i.e. the number not reset.
The operating time of the compressor in
minutes between the 2 last defrosts.
The operating time of the compressor in
minutes since last defrost. Reset after a
defrost is completed.
Fan high speed is deactivated at this
outdoor temperature and low speed is
activated.
Here, the angle of the defrost curve can
be changed using the right-hand arrow
and by either pressing + or -. (Change
the start temperature for when defrost-
ing is to begin).
By using the right-hand arrow and then
pressing +, defrost can be started manu-
ally (shunts +20°C for 10 minutes).
DEFROST
DEFROSTS
BETW. 2 DEFR
TIME SINCE DEFROST
FAN H OFF AT
DEFROST CURVE
MANUEL DEFR
VUBMF102
Adjusted by:
Not adjustable
Not adjustable
Not adjustable
By the customer, if
necessary.
By the customer, if
necessary.
By the customer, if
necessary.
Danfoss – 23