Heat Pump Information - Danfoss DHP-AL Installation And Service Instructions Manual

Table of Contents

Advertisement

2

Heat pump information

Delivery check
1. Check that there is no transport damage. The heat pump is
packaged in cardboard.
2. Remove the plastic wrapping and check that the delivery con-
tains the following components.
Sizes 6 kW - 10 kW:
Part no.
Quantity
9680-5796A00
1
9674-57902001
1
9360-47054001
1
9588-51618001
1
9360-56335001
1
9674-24735001
1
9551-54479001
1
9360-51759007
1
9674-54168001
1
3311-55300001
1
9684-48342001
2
9674-54164001
1
5211-57915001
2
9360-55453A00
1
9360-52488001
1
9360-51738005
2
9360-51738008
4
Sizes 12 kW :
Part no.
Quantity
9680-5796A00
1
9674-57902001
1
9360-47054001
1
9588-51618001
1
9360-56335001
1
9674-24735001
1
9551-54479001
1
9360-51759007
1
9674-54168001
1
3311-55300001
1
9684-48342001
2
9674-54164001
1
5211-50730A00
2
9360-56911A00
1
9360-52488001
1
9360-51738005
4
9360-51738008
2
The outdoor unit is supplied as a package containing:
• Outdoor unit
• Disassembled stand
• Necessary screws, nuts and washers.
• Defroster sensor
6
Name
Document set
Transparent binder
Safety valve 9 bar 1/2"
Kimsafe outdoor sensor 200 035
Safety valve 1.5 bar 1/2"
Expansion and bleed tank without
valve
Cardboard packaged top for HP
Compression angle joint 28x28
joint
Pipe insulation IT 9x28
Brine in Cu pipe in TWS packaging
Rubber bellows for 22-32mm hole
Pipe insulation F-54-A D=54x9mm
Flexible hose R20 L=600
Filler cock DN 25
Dirt filter with shut-off DN25
Straight connection LK 303 28xR25
Straight compression connection
22 xR20
Name
Document set
Transparent binder
Safety valve 9 bar 1/2"
Kimsafe outdoor sensor 200 035
Safety valve 1.5 bar 1/2"
Expansion and bleed tank without
valve
Cardboard packaged top for HP
Compression angle joint 28x28
joint
Pipe insulation IT 9x28
Brine in Cu pipe in TWS packaging
Rubber bellows for 22-32mm hole
Pipe insulation F-54-A D=54x9mm
Flexible hose R25 L=600
Filler cock DN 32
Dirt filter with shut-off DN25
Straight connection LK 303 28xR25
Straight compression connection
22 xR20
Dimensions and connections
The brine pipes can be connected on either the left or right-hand
sides of the heat pump.
3
Heat pump
15
5
4
6
Figure 1: Dimensions and connections.
Position Name
Heat pump
1
Brine out, during defrosting, 28 Cu
2
Return pipe water heater, 28 Cu
3
Brine in
4
Heating system supply pipe, 22 Cu: 6-10 kW, 28 Cu: 12 kW
5
Heating system return pipe, 22 Cu: 6-10 kW, 28 Cu: 12 kW
6
Brine out, normal operation
Water heater
7
Brine in, during defrosting
8
Water heater, return pipe
9
Bleed valve, at stainless steel water heater
10
Brine out, during defrosting
11
Domestic hot water, 22 Cu
12
Cold water
13
Water heater supply pipe to TWS coil
14
Brine, expansion line when outdoor unit is positioned at high level
15
Lead-in power and sensor lead
16
Lead-in sensor lead
17
Lifting point
Figure 2: Outdoor unit, Dimensions and connections.
Position Name
1
Brine in (HP Brine out) 28 Cu
2
Brine out (HP Brine in) 28 Cu
VMBME102
2
1
Water heater
14
12
17
11
10
1
2
8
7
16
13
9
2
1
1175

Advertisement

Table of Contents
loading

Table of Contents