Part 1 – Introduction
• IR LED
A sensor in the middle monitors lighting levels and
activates the IR LED during low-lighting conditions.
DC-D1223FR only
• Lens
Features a variable focus auto iris lens or a fixed focus
lens.
• Lens Rotator
Turn the lens rotator clockwise or counterclockwise
to adjust the lens' rotation angle.
• Horizontal Rotator
Used to adjust the lens' horizontal angle.
• SD Card Slot
Used to insert a microSD card into the camera. (An
SLC (Single Level Cell) or MLC (Multi Level Cell) card
by SanDisk or Transcend is recommended)
• Do not remove the SD card while the system
is in operation. Removing the card while the
system is in operation can cause the system to
malfunction and/or corrupt data stored on the
SD card.
• An SD card is a consumable product with a
finite service life. Prolonged use will damage
the card's memory sectors and result in data
loss or memory card failure. Test the SD card
regularly and replace it whenever necessary.
• Factory Reset Switch
Restores the camera's default factory settings. For
more information, refer to the Factory Reset.
• Ceiling Installation Hole
Used to screw the camera in place on a ceiling.
• I/O Device Port
Used to connect I/O devices to the camera.
• Vertical Rotation Adjustment Screw
Used to adjust the lens' angle and lock it in place.
10
Factory Reset
Only use the factory reset switch to restore the camera
to its factory default settings.
A factory reset will clear all camera settings configured
by the user.
1
Shut off the power supply, insert a straight pin into
the switch hole, and press down on the reset switch.
2
Hold the switch down and reconnect the power
adapter.
3
Once the device turns back on and its LEDs start
blinking, wait 5 seconds and then remove the pin.
4
The device will go through the resetting process and
reboot. All camera settings will be restored to their
factory defaults after the reboot.
It's also possible to do a factory reset by pressing and
releasing the reset switch while the camera is turned
on or using the IDIS Discovery program from a remote
location. A factory reset will reboot the system. For more
information on factory reset, refer to the IDIS Discovery
operation manual.