ACT Image Spot 50 CW

DMX Addressing

In a setup with multiple devices, make sure that you set the DMX starting address of each device
correctly. The ACT Image Spot 50 CW has 2 personalities: 2 channels and 3 channels.
If you want to connect multiple devices on one data link and use them in 3-channel mode, for example,
follow the steps below:
Set the starting address of the 1
Set the starting address of the 2
Set the starting address of the 3
Continue assigning the starting addresses of the remaining devices by adding 3 to the previous
number each time.
Make sure that you do not have any overlapping channels in order to control each ACT Image Spot 50
CW correctly. If two or more devices are addressed similarly, they will work similarly.

Beam Angle Adjustment

The beam angle of the ACT Image Spot 50 CW can be adjusted manually in the range 15,2°–27,5°. To
adjust the beam angle, follow the steps below (see Fig. 13):
Turn the zoom control (05) counterclockwise to loosen it.
Slide the zoom control (05) forwards or backwards to achieve the desired beam angle.
After adjusting the beam angle, turn the zoom control (05) clockwise to tighten it. Do not
overtighten it.
Product code: 34060
device on the data link to 1 (001).
st
device on the data link to 4 (004), as 1 + 3 = 4.
nd
device on the data link to 7 (007) as 4 + 3 = 7.
rd
18