Summary of Contents for SHOWTEC Cameleon Spot Q4

  • Page 1 MANUAL ENGLISH Cameleon Spot Q4 Ordercode: 42673 Highlite International B.V. – Vestastraat 2 – 6468 EX – Kerkrade – the Netherlands...
  • Page 2: Table Of Contents

    Cameleon Spot Q4 Table of contents Warning ....................................2 Safety Instructions ................................. 2 Operating Determinations ............................4 Rigging .................................... 4 Connection with the mains............................5 Return Procedure ................................6 Claims ....................................6 Description of the device ..............................7 Optional accessories..............................7 Frontside..................................
  • Page 3: Warning

    Save the carton and all packing materials. In the event that a fixture must be returned to the factory, it is important that the fixture be returned in the original factory box and packing. Your shipment includes: ● Showtec Cameleon Spot Q4 ● 1x Schuko to 3-pins (IP-65 ) Power cable 1,5m ●...
  • Page 4 Cameleon Spot Q4 Before the initial start-up, please make sure that there is no damage caused by transportation. Should there be any, consult your dealer and do not use the device. To maintain perfect condition and to ensure a safe operation, it is absolutely necessary for the user to follow the safety instructions and warning notes contained in this manual.
  • Page 5: Operating Determinations

    Cameleon Spot Q4 ● If your Showtec device fails to work properly, discontinue the use immediately. Pack the unit securely (preferably in the original packing material), and return it to your Showtec dealer for service. ● For adult use only. The device must be installed beyond the reach of children. Never leave the unit running unattended.
  • Page 6: Connection With The Mains

    The Cameleon Spot Q4 can be placed on a flat stage floor or mounted to any kind of truss with a clamp. Improper installation can cause serious injuries and/or damage of property! Connection with the mains Connect the device to the mains with the power-plug.
  • Page 7: Return Procedure

    Cameleon Spot Q4 Return Procedure Returned merchandise must be sent prepaid and in the original packing, call tags will not be issued. Package must be clearly labeled with a Return Authorization Number (RMA number). Products returned without an RMA number will be refused. Highlite will not accept the returned goods or any responsibility.
  • Page 8: Description Of The Device

    Cameleon Spot Q4 Description of the device Features The Cameleon Spot Q4 is a spotlight with great output and effects. It is an extension on our Cameleon series. It's an indoor and outdoor solution for illumination of numerous objects. ●...
  • Page 9: Frontside

    Cameleon Spot Q4 Frontside Fig.01 01) Mounting bracket with inclination screws 02) 1x 15W 4-in-1 RGBW LED 03) Safety eye Backside Fig.02 04) OLED Display + control buttons 05) Special mini 3-pin power cable IN/OUT IP-65 06) Special mini 3-pin DMX cable IN/OUT IP-65...
  • Page 10: Installation

    Cameleon Spot Q4 Installation Remove all packing materials from the Cameleon Spot Q4. Check if all foam and plastic padding is removed. Connect all cables. Do not supply power before the whole system is set up and connected properly. Always disconnect from electric mains power supply before cleaning or servicing.
  • Page 11: Multiple Cameleon Spots (Dmx Control)

    Cameleon Spot Q4 Multiple Cameleon Spots (Master/Slave control) Fig. 03 Multiple Cameleon Spots (DMX Control) 01) Fasten the effect light onto firm trussing. Leave at least 0,5 meter on all sides for air circulation. 02) Always use a safety cable (ordercode 70140 / 70141).
  • Page 12 Cameleon Spot Q4 Multiple Cameleon Spots DMX Set Up Fig. 04 Note : Link all cables before connecting electric power Note: You cannot plug a standard DMX cable directly into the connector. Be sure to use the special cable for DMX connection (42708) and extension cables (42707/427076).
  • Page 13: Fixture Linking

    DMX Extension cable for Cameleon series (3m) 427076 DMX Extension cable for Cameleon series (6m) 42708 DMX Input cable for Cameleon series (3m) The Cameleon Spot Q4 can be operated with a controller in control mode or without the controller in stand-alone mode. Ordercode: 42673...
  • Page 14: Control Panel

    Cameleon Spot Q4 Control Panel A) OLED Display MODE button C) SET button D) UP button DOWN button Fig. 05 Control Mode The fixtures are individually addressed on a data-link and connected to the controller. The fixtures respond to the DMX signal from the controller. (When you select the DMX address and save it, the controller will display the saved DMX address, next time.)
  • Page 15: Menu Overview

    Cameleon Spot Q4 Menu Overview Ordercode: 42673...
  • Page 16: Main Menu Options

    Cameleon Spot Q4 The Cameleon Spot Q4 will show the current software version, run mode and actual temperature at start- up ! Main Menu Options 01) Press the SET button to open the main menu. 02) Press the UP/DOWN buttons to scroll through the menu. The display will show: 03) Press the SET button to open the desired menu.
  • Page 17: Auto Program

    Cameleon Spot Q4 Press the UP/DOWN buttons to set the intensity from the desired colors, the adjustment ranges are between: Green Blue White 3. Auto program In this menu you can activate the built-in auto program. 01) While in main menu, press the UP/DOWN buttons until the display shows Auto.
  • Page 18: Master/Slave

    Cameleon Spot Q4 5. Master/slave In this menu you can set the device as a slave. 01) While in main menu, press the UP/DOWN buttons until the display shows Slave. 02) Press the SET button to open the menu, the display will show: 03) If you choose Yes, the device will become a slave.
  • Page 19: Dimmer Speed

    Cameleon Spot Q4 6.2. Dimmer Speed In this menu you can adjust the dimming speed of the device. 01) Press the UP/DOWN buttons until the display shows Dimmer Speed. 02) Press the SET button to open the menu, the display will show: 03) Press the UP/DOWN buttons to choose between Fast or Smooth.
  • Page 20: Dmx Sync

    Cameleon Spot Q4 6.5. DMX Sync In this menu you can set the DMX synchronisation of the device. 01) Press the UP/DOWN buttons until the display shows Dmx Sync. 02) Press the SET button to open the menu, the display will show: 03) Press the UP/DOWN buttons to select On or Off.
  • Page 21: Information

    Cameleon Spot Q4 7. Information In this menu you can view several pieces of information about the device. While in main menu, press the UP/DOWN buttons until the display shows Information. Press the SET button to open the menu, the display will show: 03) You can view the currently installed software version, actual temperature, lifetime of the LED and device code.
  • Page 22: Dmx Channels

    Cameleon Spot Q4 10 DMX Channels Channel 1 – Master dimmer intensity 0-255 Gradual adjustment, from dark to brightest 0-100% Channel 2 – Linear Strobe (CH1 and CH7, CH8, CH9 or CH10 must be set between 1-255 and CH4 between 8-255 and CH5 between 16-255...
  • Page 23 Cameleon Spot Q4 Channel 5 – Built-in programs (CH1 and CH6 must be set between 1-255 0-15 No function 16-31 Jump 1 32-47 Jump 2 48-63 Jump 3 64-79 Jump 4 80-95 Jump 5 96-111 Jump 6 112-127 Jump 7...
  • Page 24: Maintenance

    04) The electric power supply cables must not show any damages or material fatigue. The Cameleon Spot Q4 requires almost no maintenance. However, you should keep the unit clean. Otherwise, the fixture’s light-output will be significantly reduced. Disconnect the mains power supply, and then wipe the cover with a damp cloth.
  • Page 25 Cameleon Spot Q4 Problem Probable cause(s) Solution No power to the fixture • Check if power is switched on and One or more cables are plugged in fixtures do not function at all Internal fuse blown • Return the Cameleon Flood to...
  • Page 26: Product Specifications

    Cameleon Spot Q4 Product Specifications Model: Showtec Cameleon Spot Q4 Input Voltage: 100-240 VAC, 50/60Hz Power consumption: 23W@FO DMX linking: 30 pcs Drive current: 900mA Power factor: 0,49 Protection rate: IP-65 Dimensions: 155 x 235 x 195 mm (LxWxH incl. bracket)
  • Page 27: Dimensions

    Cameleon Spot Q4 Dimensions Ordercode: 42673...