ACT Fresnel 50 RGBAL incl. barndoor
DMX Addressing
In a setup with multiple devices, make sure that you set the DMX starting address of each device
correctly. The ACT Fresnel 50 RGBAL has 3 personalities: 5, 8 and 12 channels.
If you want to connect multiple devices on one data link and use them in 12-channel mode, for
example, follow the steps below:
Set the starting address of the 1
Set the starting address of the 2
Set the starting address of the 3
Continue assigning the starting addresses of the remaining devices by adding 12 to the previous
number each time.
Make sure that you do not have any overlapping channels in order to control each ACT Fresnel 50
RGBAL correctly. If two or more devices are addressed similarly, they will work similarly.
Product code: 34014
device on the data link to 1 (001).
st
device on the data link to 13 (013), as 1 + 12 = 13.
nd
device on the data link to 25 (025) as 13 + 12 = 25.
rd
19