Parameter description
209
Current limit (I
)
LIM
(Current limit)
210
Warning
frequency low (f
)
LOW
(LOW freq warn)
211
Warning
frequency high (f
)
HIGH
(HI freq warn)
212
Warning
current low (f
)
LOW
(Lo curr. warn)
213
Warning
current high (f
)
HIGH
(Hi curr. warn)
214
Ramp type
(Ramp type)
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Value:
0.0 - I
VLT,MAX
Value:
0.0 - f
RANGE
Value:
0.0 - f
+ 10%
RANGE
Value:
0.0 - I
VLT,MAX
Value:
0.0 - I
VLT,MAX
Value:
Linear (linear)
Sine shape (s curve 1)
Sine
2
shape (s curve 2)
Sine
3
shape (s curve 3)
= Factory setting. Text in ( ) = Display text.
The figures in [ ] are used in bus communication.
®
MG.30.A7.02 - VLT
is a registered Danfoss trademark
Max. allowable output current. The
factory-set value corresponds to a 160%
Depending
on unit
load of the rated motor size.
Not applicable to all types.
Settings between 105% and 160% may
only be applied on intermittent operation.
If the set value is too low the motor will not
start.
This value sets the lower warning frequen-
cy f
of the normal frequency converter
0.0
LOW
operation range, see page 71.
If the output frequency is below f
display shows FREQ. VAR. LOW.
The signal outputs can be programmed
to give a warning signal (parameters
407-410).
This value sets the higher warning frequen-
cy f
132 H
Z
HIGH
operation range, see page 71. If the output
frequency is higher than f
shows FREQ. VAR. HIGH. The signal out-
puts can be programmed to give a warning
signal (see parameters 407-410).
This value sets the lower warning current
I
of the normal frequency converter op-
0.0
LOW
eration range, see page 71.
If the output current is below I
display shows CURR VAR. LOW.
You can program the signal outputs to give
an alarm signal (see parameters 407-410).
This value sets the higher warning current
I
of the normal frequency converter op-
I
HIGH
VLT,MAX
eration range, see page 71. If the output
current is higher than I
shows CURR VAR. HIGH. The signal out-
puts can be programmed to give a warning
signal (see parameters 407-410).
Select the shape of the ramp up and the
ramp down. The sine shapes give a softer
[0]
[1]
start and stop of the acceleration and
[2]
deceleration.
[3]
The sinusoidal ramps cannot be set with
steps as small as the linear ramp, even
though the display indication appears to be
continuous.
2.. References and limits
LOW
of the normal frequency converter
the display
HIGH
LOW
the display
HIGH
the
the
95

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents