Immunity
136
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
EMC testresults
VLT
3011-3052 380-500V, VLT
®
Basic standard
Burst
IEC 1000-4-4
Acceptance criterion
B
Port
connection
CM
Line
OK
Motor
OK
Brake
OK
Control lines
OK
PROFIBUS option
OK
Signal interface < 3 m
OK
Enclosure
-
Line
2kV/5kHz/DCN
Motor
2kV/5kHz/CCC
Brake
2kV/5kHz/CCC
Control lines
2kV/5kHz/CCC
PROFIBUS option
2kV/5kHz/CCC
Signal interface < 3 m
1kV/5kHz/CCC
Enclosure
-
Acceptance criteria according to: IEC 22G/21/CDV, EN50082-2, 175R0740
DM: Differential mode
CM: Common mode
CCC: Capacitive clamp coupling
DCN: Direct coupling network
VLT
3060-3250 380-500V, VLT
®
Basic standard
Burst
IEC 1000-4-4
Acceptance criterion
B
Port
connection
CM
Line
OK
Motor
OK
Control lines
OK
PROFIBUS option
OK
Signal interface < 3 m
OK
Enclosure
-
Line
4kV/5Hz/CCC
Motor
2kV/5Hz/CCC
Control lines
2kV/5Hz/CCC
PROFIBUS option
2kV/5Hz/CCC
Signal interface < 3 m
1kV/5Hz/CCC
Enclosure
-
Acceptance criteria according to: IEC 22G/21/CDV, EN50082-2, 175R0740
DM: Differential mode
CM: Common mode
CCC: Capacitive clamp coupling
DCN: Direct coupling network
®
MG.30.A7.02 - VLT
is a registered Danfoss trademark
3006-3022 200V
®
Surge
ESD
Radiated elec-
IEC 1000-4-5
IEC 1000-4-2
tromagn. field
IEC 1000-4-3
B
B
DM
CM
OK
OK
-
-
-
-
-
-
-
-
OK
-
-
-
-
-
-
-
-
-
OK
2kV/2
4kV/12
-
-
-
-
-
-
-
-
2kV/2 *
-
-
-
-
-
-
-
8 kV AD
-
-
10V/m
6 kV CD
* Injection on cable shield
** 2,3 x Û
3032-3052 200V
®
Surge
ESD
Radiated elec-
IEC 1000-4-5
IEC 1000-4-2
tromagn. field
IEC 1000-4-3
B
B
DM
CM
OK
OK
-
-
-
-
-
OK
-
-
-
-
-
-
-
-
-
OK
1kV/2
2kV/12
-
-
-
-
-
2kV/2 *
-
-
-
-
-
-
-
8 kV AD
-
-
10V/m
6 kV CD
* Injection on cable shield
** 2,3 x Û
M
V
A
-
-
-
-
-
-
OK
-
*
-
-
-
-
-
: max. testpulse 1250 V peak
N
M
V
A
-
-
-
-
-
OK
-
*
-
-
-
-
: max. testpulse 1350 V peak