Danfoss VLT 3006 Product Manual page 28

Table of Contents

Advertisement

Mains supply 3 x 440/460/500 V
According to international VDE and UL/CSA requirements
Constant torque (CT):
Output current
Output
Typical shaft output
Quadratic torque (VT):
Output current
Output
Typical shaft output
Max. cable cross-section
Max. motor cable length
Output voltage
Output frequency
Rated motor voltage
Rated motor frequency
Thermal protection during operation
Switching on output
Ramp times
Input current
Quadratic load
Max. cable cross-section
Max. pre-fuses
Supply voltage (VDE 0160)
Supply frequency
Power factor / cos. ϕ
Efficiency
Switching on input
Weight (kg)
Power loss at max. load CT [W]
Power loss at max. load VT [W]
Enclosure
Vibration test
Relative humidity
Ambient temperature
(to VDE 0160)
Frequency converter protection
EMC standards
(See section "EMC test results")
1) Bussman rapid type JJS integrated.
2) In the range -10 to 0°C, the equipment can start and run; however, the display values and certain operating characteristics will not fulfil the
specifications.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
VLT type
I
VLT,MAX
S
VLT,N
S
(60s) [kVA]
VLT,MAX
P
VLT,N
I
VLT,MAX
S
VLT,N
P
VLT,N
VLT type
I
L,MAX
I
L,MAX
1)
1
times/min.
VLT type
Heat sink
Heat sink
Emission
Immunitet
®
MG.30.A7.02 - VLT
is a registered Danfoss trademark
3060
3075
I
[A]
77
96
VLT,N
[A](60s)
116
144
[kVA]
67
83
100
125
[kW]
55
75
I
[A]
96
124
VLT,N
[A](60s)
106
136
[kVA]
83
107
[kW]
75
90
2
[mm
]
70
70
[m]
300
U
[%]
0-100 of mains voltage
M
f
[Hz]
0-120 or 0-500; programmable
M
U
[V]
380/400/415/440/460/500
M,N
f
[Hz]
50/60/87/100
M,N
Integrated thermal motor protection (electronic); thermistor
to DIN 44081
Unlimited (frequent switching on output may result in fault message)
[s]
0.1 - 3600
3060
3075
I
[A]
75.8
94.4
123.4
L,N
(60s)[A] 113.7
141.6
185.1
I
[A]
94.4
123.4
155.3
L,N
(60s)[A] 106.0
136.0
172.0
[mm2] 120.0
120.0 2 x 120 2 x 120 2 x 120
[A] 150.0
150.0
250.0
[V]
3 x 380/400/415/440/460/500 ±10%
[Hz]
50/60
0.9/1.0
0.96 at 100% load
1
3060
3075
IP 21
147
147
IP 54
147
147
Front
423
529
859
1074
Front
529
713
1074
1447
IP 21 / IP 54, NEMA 1/12
[g]
0.7
[%]
VDE 0160 5.2.1.2.
[°C]
-10→ +40 at full load
[°C]
-30/25→ +65/70 in storage/transport
Jord- og kortslutningssikker
EN 55011, EN 55014
EN 50082-2, IEC 1000-4-2, IEC 1000-4-3, IEC 1000-4-4,
IEC 1000-4-5 VDE 0160
Technical data
3100
3125
3150
3200
124
156
180
240
186
234
270
360
107
135
156
208
161
203
234
312
90
110
132
160
156
180
240
302
172
198
264
332
135
156
208
262
110
132
160
200
150
150
150
2 x 95
3100
3125
3150
3200
155.3
177.1
238.9
233.0
265.7
358.4
177.1
238.9
307.6
198.0
264.0
332.0
2 x 240 2 x 240
250.0
300.0
450.0
3100
3125
3150
3200
211
211
220
306
211
211
220
306
713
910
1091
1503
1447
1847
2216
3051
910
1091
1503
1812
1847
2216
3051
3679
2)
(VT) -10→ +45 (CT)
3250
302
453
262
392
200
361
397
313
250
2 x 95
3250
307.6
461.4
359.3
397.0
500.0
3250
306
306
1812
3679
2209
4485
2)
27

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents