6.12 SKYAIR®
SkyAir supplies compressed air to the platform. A filter/regulator located in the platform
controls air pressure. The on/off switch is located in the engine compartment. This
accessory receives power from the SkyPower system.
6.12.1
Compressor Specifications
Single stage with dual control
CFM displacement: 9.3
Motor: 230 V, 2 hp, 3-phase
6.12.2
Accessory Ratings
CONTROL MODE
Automatic Start-Stop Control
Constant Run Control
6.12.3
Safety Precautions
Do not overload platform.
Ensure no personnel are beneath platform.
This factory-installed option is available only on specified models.
800S, 860SJ
Figure 39. SkyAir System
WARNING
31222372
Accessories
BM000005A
VOLUME
100 - 130 psi
105 - 120 psi
115