5.6.4
Notification Assembly
1. Override Button
2. Bi-color LED
5.6.5
LED Indicator
A bi-color LED indicator on the platform control box signals Sky- Sense activity.
No LED: Normal operation.
LED Flashing Yellow: Machine is in SkySense warning zone and will reduce to
elevated drive height speed. Flash frequency correlates to closeness of the object.
LED Red: Machine is in SkySense stop zone and all machine functions will cease.
LED Flashing Red: SkySense sensor is obstructed or damaged. Obstructions must be
removed and proper function verified. Damaged sensors must be replaced.
5.6.6
SkySense Alarm
Activation of SkySense is also signalled by an audible alarm that indicates SkySense
activity when reaching the warning or stop zones.
In the warning zone, the audible alarm will pulse and increase in frequency as the
machine moves closer to the object. In the stop zone, the alarm will sound a continuous
tone.
Additionally, when the machine is in the stop zone, the platform control panel audible
alarm will sound, indicating activation of the SoftTouch system. Reset the system by
releasing the trigger switch.
Audible SkySense alarms can be muted, although LEDs will continue to light.