JLG ES1330L Operation & Safety Manual page 43

Table of Contents

Advertisement

MDI Indicator (If Equipped)
The Multifunction Digital Indicator (MDI) displays a Battery
Discharge Indicator (BDI), a LCD display showing the current
hourmeter reading, a system distress LED, and Diagnostic
Trouble Codes (DTC) when a functional problem occurs with
the machine.
When a problem occurs and a DTC Code displayed:
A LED wrench icon (1) LED illuminates.
A three to five digit DTC code will display on the DTC
LCD display (2) below the wrench icon.
Note: When more than one DTC exists, each DTC will be
displayed on the LCD for three seconds before chang-
ing to the next DTC. Once the last active DTC is dis-
played, the display will recycle indefinitely until the
DTCs are corrected. For DTCs and descriptions, refer
to Diagnostic Trouble Codes.
Also located on the MDI are Battery Discharge Indicators (BDI) (3, 4, 5). The three green LEDs indicate the level
of charge (voltage) remaining in the batteries.
Note: When the battery voltage is low and will need a charge soon, the yellow LED (4) begin to flash.
BDIs and the hourmeter display under normal operating conditions. When a DTC exists other than 00x DTCs, the
BDI LEDs and hourmeter are not be displayed. Additionally, when the platform is elevated and the machine is
driving in creep mode, the turtle icon is displayed.
Overload Indicator (LSS)
The Overload Indicator indicates when the platform has been overloaded. An audible
alarm will also signal when the platform is overloaded.
Note: If the Overload Indicator is illuminated, further elevation will be prevented. Re-
duce the weight in the platform to not exceed the rated workload indicated on
the capacity decal, then the controls will work again.
Note: When ambient temperatures are below freezing, the LSS will have a reduction in
available capacity. This will trigger the LSS before achieving the maximum allow-
able capacity.
Platform Lift/Lower Switch
A three position, momentary contact lift control switch provides raising and lowering of
the platform from the Ground Control Station.
Note: There will be a brief delay between switch activation and movement of the
platform.
When operating platform from the ground controls, activate the Lift/Lower switch to up
position and hold to raise platform, or down position and hold to lower an elevated
platform. Release to stop all movement.
ES1330L, ES1530L
Machine Controls, Indicators, and Operation
5
4
1. System Fault LED
Indicator (RED LED)
2. Hourmeter/DTC
Code Display
3. 100% Battery
Charge Indicator
(GREEN AREA)
31221553
1
000000
3
4. Battery Charge
LOW Indicator
(YELLOW AREA)
5. Battery Re-Charge
Indicator (RED AREA)
2
43

Advertisement

Table of Contents
loading

This manual is also suitable for:

Es1530l