JLG ES1330L Operation & Safety Manual page 73

Table of Contents

Advertisement

5.3.1
Specifications
Electrical System Voltage (DC)
Power Inverter:
DC Input:
AC Output:
Protection:
5.3.2
Safety Precautions
This accessory may cause shock or electrocution if used improperly. Treat inverter
output the same as commercial AC power.
This inverter will only operate from a 24V power source. Do not attempt to connect
the inverter to any other power source, including any AC power source.
Do not allow water or other liquids to contact the inverter.
Do not use appliances with damaged or wet cords.
Route appliance cords and extension cords to prevent accidental pinching, crushing,
abrading, and tripping hazards.
Do not use the inverter near flammable materials or in any locations that may
accumulate flammable fumes or gases. This is an electrical device that can briefly
spark when electrical connections are made or broken.
5.3.3
Operation
1. Set the inverter ON/OFF switch to the ON position at the ground control station.
2. Only plug in tools or appliances rated within the maximum output wattage at the
platform AC receptacle mounted on the platform.
ES1330L, ES1530L
DESCRIPTION
DC Input Voltage:
Operating Temperature:
Output Power (Continuous):
Output Power (Surge):
Output Power (AC):
Output Voltage (AC):
Output Frequency:
Output Reverse DC Polarity:
DANGER
SPECIFICATION
Power Bright
20 to 30 VDC
-4° F (-20° C) to 113° F (+45° C)
900W
1800W
7.5A
117V+/– 10%
60 Hz
Type:
Modified Sine Wave
3 X 25A Replaceable Fuse
31221553
Accessories
24V