Storage; Inverter Storage; Battery Storage; Unpacking - Alpha ESS SMILE-S6-HV Installation Manual

Energy storage system
Hide thumbs Also See for SMILE-S6-HV:
Table of Contents

Advertisement

STORAGE

04
Storage

4.1 Inverter Storage

The following requirements should be met if the inverter is not put into use directly:
1. Do not unpack the inverter.
2. Keep the storage temperature at -40~70°C and the humidity at 5%~95% RH.
3. The inverter should be stored in a clean and dry place and be protected from dust and
water vapor corrosion.
4. A maximum of six inverters can be stacked. To avoid personal injury or device damage,
stack inverters with caution to prevent them from falling over.
5. During the storage period, check the inverter periodically. (It is recommended that the
check is performed every three months.) Replace the packing materials that are damaged
by insects or rodents in a timely manner.
6. If the inverters have been stored for more than two years, it must be checked and
tested by professionals before being put into use.

4.2 Battery Storage

The following requirements should be met if the battery pack is not put into use directly:
1. Place batteries according to the signs on the packing case during storage. Do not put
batteries upside down or sidelong.
2. Stack battery packing cases by complying with the stacking requirements on the
external package.
3. Store the battery pack out of reach of children and animals.
4. Store the battery pack where it should be minimal dust and dirt in the area.
5. Handle batteries with caution to avoid damage.
6. The storage environment requirements are as follows:
– Ambient temperature: -10~55°C, recommended storage temperature: 15~30°C
– Relative humidity: 15%~ 85%
– Place batteries in a dry and clean place with proper ventilation.
– Place batteries in a place that is away from corrosive organic solvents and gases.
– Keep batteries away from direct sunlight.
– Keep batteries at least 2 m away from heat sources.
7. The batteries in storage must be disconnected from external devices. The indica-tors (if
any) on the batteries should be off.
8. Batteries should be delivered based on the "first in, first out" rule.
9. The warehouse keeper should collect battery storage information every month and
periodically report the battery inventory information to the planning department. The
batteries that have been stored for nearly 6 months should be recharged timely.
10. If a lithium battery is stored for a long time, capacity loss may occur. After a lithi-um
battery is stored for 12 months in the recommended storage temperature, the
irreversible capacity loss rate is 3%~10%. It is recommended that batteries not be stored
for a long period. If the batteries need to be stored for more than 6 months, it is
recommended to recharge the batteries to 65~75% of the SOC. For example, they can be
recharged every 6 months at least, and must be recharged to at least 50% of the SOC.
16
17
05

Unpacking

5.1 Checking the Outer Packing

Before unpacking the battery pack and inverter, check the outer packing for damage,
such as holes and cracks. If any damage is found, do not unpack the product and contact
your distributor as soon as possible.

5.2 Scope of Delivery

Check the scope of delivery for completeness and any externally visible damage.
Contact your distributor if the scope of delivery is incomplete or damaged.
Inverter
(X1)
PV+&PV-
Connectors (X2)
Ring Terminal
Lug (X2)
Installation Manual
(X1)
SMILE-S6-HV-INV Hybrid Inverter
Upper Wall
Lower Wall
Bracket (X1)
Bracket (X1)
Paper Plate (X1)
Cord End
10 Pin Terminal
WiFi Module
Terminal (X8)
Block (X1)
Screw M5*10 (X2)
T20 Screwdriver
Screw M6*16 (X3)
(X1)
Grid Magnet Ring
Side Gasket
(X1)
(X1)
UNPACKING
Inverter
Wall Anchor
Positioning
ST6*55 (X6)
(Optional)
Indoor Use
Outdoor Use
Terminal
(X1)
Resistor (X1)
GRID CT
GRID CT
CT (X1)
CT Cable (X1)
(Optional)
(Optional)
Cord End Terminal
Wire Cover
for 10mm
cable
2
(X1)
(X4) (Optional)

Advertisement