Fault Findings - ESAB EASY-WELD SSR 400 Instructions Manual For Installation, Operation And Maintenance

Fully thyristorised welding rectifier (mma)
Table of Contents

Advertisement

FAULT FINDING
Abnormal Condition
A.
Welding / automatically
stops and the bottom
WARN LAMP glows
B.
The current adjustment
does not work
Cause
Control fuse on the front
panel blown
The equipment is over
loaded
Loose Connection
Faulty VR1 variable
potentiometer of current
control on the front panel of
the power source or remote
controller unit.
Remote / Local Switch not
in proper position.
Fault in control PCB
(ZMAT/D-70 OR ZMAT/D-
720)
Fault in Firing PCB ZMAT D
110
One phase is missing
Main SCR damaged
8
Remedy
Replace with rated fuse
In case of the equipment is
being operated under duty
cycle higher than that of
specified and /or higher
output current, the bottom
WARN LAMP will glow. In
such case, wait and keep
the power switch 'ON' to
keep the fan running at on
load condition. After 5 to 10
minutes, the WARN LAMP
will turn off and then adjust
the welding current and /or
duty cycle and restart
welding.
Avoid the Welding
operation while Indicator
lamp "WARN" is repeatedly
'ON'
Fasten the plug & socket
firmly.
Check with a multimeter,
replace, if found defective.
Check the position of the
Remote / Local switch and
position properly.
Replace control PCB
Replace Firing PCB
Check and rectify input
supply voltage
Replace SCR