5 - 4
l M a i n t e n a n c e

C h e c k i n g t h e D e w p o i n t

4
Turn on the dryer.
5
Turn on the portable instrument, and ensure there is positive airflow through
the sensor.
6
Monitor the readout and allow ample time for it to stabilize before
disconnecting the portable instrument. Some dewpoint monitors require a
substantial amount of time for residual moisture to be purged from the sensor.
7
In the event the dewpoint is not satisfactory, refer to the Troubleshooting
section of the manual, under Process Dewpoint alarm for DC2.
8
Stop the dryer and allow it to cool down. After the dryer has cooled,
disconnect the portable instrument and replace any pipe plugs that may have
been removed.
9
Replace the plastic cover on the dryer.
( c o n t i n u e d )