4 - 2 2
l O p e r a t i o n
C o n t r o l F u n c t i o n D e s c r i p t i o n s
S c r e e n
SCREEN 50
PROCESS DEWPOINT
TRIM UP LIMIT
SCREEN 51
PROCESS DEWPOINT
TRIM LOW LIMIT
SCREEN 52
PROCESS DEWPOINT
GAIN
SCREEN 53
PROCESS DEWPOINT
DEADBAND
SCREEN 54
PROCESS DEWPOINT
CONTROL RESET
SCREEN 55
AUTO START TIMER
ENABLED
F u n c t i o n
This is the maximum value the
dewpoint control can set the regeneration
temperature to achieve the desired
375°F
dewpoint.
This is the minimum value the dewpoint
control can set the regeneration
temperature to achieve the desired
100°F
dewpoint.
This is the proportional gain value for the
dewpoint control.
0.7
This is the deadband range. If the actual
dewpoint value is within this range of the
dewpoint setpoint, the control will not
1
make a change to the regeneration
temperature.
This will reset the dewpoint control back
to the factory default values.
This screen is used to enable or disable the
auto start function. If the function is
enabled, the dryer can be started or
EDIT
stopped once each day. The start and stop
times and days can be set on screens 56
and 57.
( c o n t i n u e d )