Checking The Dewpoint; C H E C K I N G T H E D E W P O I N T - Conair Carousel Plus UGD043-1216 User Manual

Table of Contents

Advertisement

NOTE: The dryer control is
averaging the dewpoint over
time. Allow the system to
stabilize to ensure an accurate
reading.
5 - 4
l M a i n t e n a n c e

C h e c k i n g t h e D e w p o i n t

It is a good idea to monitor the dewpoint performance of your dryer periodically
with a calibrated portable dewpoint monitor, to ensure it is performing at maximum
capacity. Even if your dryer has a dewpoint readout, comparing it to a portable
instrument periodically will confirm that the dewpoint sensor and readout is per-
forming properly.
To check dewpoint:
1
Connect your portable dewpoint meter to the
dewpoint check port on the rear panel of the
dryer.
2
Turn on the portable instrument, and ensure
there is positive airflow through the sensor.
3
Monitor the readout and allow ample time for it to stabilize before discon-
necting the portable dewpoint monitor. Some dewpoint monitors require a
substantial amount of time for residual moisture to be purged from the sensor.
4
In the event the dewpoint is not satisfactory,
tion of this manual, under Delivery Air Dewpoint alarm.
refer to the Troubleshooting sec-

Advertisement