Conair W Series User Manual page 115

Carousel plus dryer
Table of Contents

Advertisement

Replacement dewpoint
monitors are available
from Conair.
Contact Conair Parts
(800) 458 1960
From outside of the
United States, call:
(814) 437 6861
Problem
Dryer dewpoint is not
reaching proper setpoint.
Po o r M a t e r i a l D r y i n g
Tr o u b l e s h o o t i n g
Dewpoint - The process air must be at a low dewpoint so it can efficiently collect
the moisture as it is released from the heated material and carry it to the dryer to be
removed in the desiccant. In most cases, the dryer will dry your material satisfacto-
ry if the dewpoint of the air is -20 to -40° F {-29 to -40° C}. If your dryer does not
have a dewpoint readout, you can check the dewpoint with a portable dewpoint
instrument. Conair sells a variety of portable dewpoint meters. Contact Conair
Parts.
Possible cause
Low regeneration temperature.
Poor regeneration airflow.
High dewpoint, ambient air leaking into
the closed loop drying circuit.
Return air temperature to the dryer is too
high.
Poor desiccant performance.
( c o n t i n u e d )
Solution
Replace or check defective heaters, fuses
etc.
Clean or replace the regeneration filter.
Ensure the regeneration blower is
operating properly and rotating in the
correct direction. See Installation section
entitled, Checking for proper air flow.
Remove obstructions in the air stream,
such as crimped hoses, etc.
Replace damaged hoses and seal any
leaks in the process air circuit.
If using a vacuum loader on the hopper,
ensure that the loader shroud is installed
in the hopper and that the hopper is
completely filled with material.
If partially filling your hopper, ensure
that the hopper loader is sealed against
ambient air.
Install a gasket between the loader and
the top of the hopper.
Clean aftercooler coils. See Maintenance
section entitled, Cleaning the aftercooler
coils.
See Troubleshooting section, entitled
Replacing the desiccant wheel assembly.
Tr o u b l e s h o o t i n g l
6 - 2 5

Advertisement

Table of Contents
loading

This manual is also suitable for:

W 15W 25W 50W 75W 100

Table of Contents