Volatile trap - The volatile trap is recommended if drying materials that
produce volitales that condense into a waxy or oily residue and/or if the
material contains excessive fines. (Used only in conjunction with the standard
aftercooler.)
•
Precooler - The precooler reduces the temperature of air flow after the
desiccant wheel and before the process heater, enables the dryer to control
temperatures at low setpoints (100º - 150ºF {38º - 66ºC}).
•
Filter check - The filter check sensor will activate a passive alarm when the
process filter is clogged or needs to be replaced.
•
Heater current monitor - The heater current monitor measures the total
amperage across both the process and regeneration heaters and the
pre-determined power consumption values for the blowers and the control.
•
CFM monitor - The CFM monitor measures the cubic feet per minute of air
flow across the inlet/outlet of the process blower.
•
Communications - Allows the dryer to be networked to industrial control
systems. DeviceNet is standard. Modbus, SPI and Ethernet are available.