Problem
Dryer not producing desired
dewpoint.
6 - 2 0
l Tr o u b l e s h o o t i n g
D e w p o i n t Tr o u b l e s h o o t i n g
Under normal operating conditions, the dryer will produce dewpoints in the range
of -40 to -20° F {-40 to -29° C}. However, you may experience situations that pro-
duce undesirable results.
Possible cause
Return air temperature exceeds 125°F
{52°C}.
Regeneration temperature is below nor-
mal setting.
Low regeneration air flow.
Leaks in process lines.
Contaminated desiccant due to off-
gassing, too long of a residence time or
drying temperature is too high for the
grade of material being processed.
Analog option board/sensor malfunction
Solution
Reduce the temperature of the cooling
water to the aftercooler or increase the
flow.
Check amperage of regeneration heaters.
Replace heaters if necessary.
WARNING: Any electrical
checks should be performed
by a qualified electrician.
Check regeneration filter and clean
and/or replace as necessary.
Check all hoses, gaskets, doors, loaders
or other potential areas where leakage
may occur. Replace any defective hoses
or gaskets.
Verify proper drying temperatures and
residence times. If off-gassing is a
condition of the material being
processed, contact Conair Parts for
the addition of a volitale trap.
Verify dryer dewpoint readings with a
calibrated portable dewpoint meter.
Replace analog option board or sensor.