Setback Feature Guidelines - Conair W Series User Manual

Carousel plus dryer
Table of Contents

Advertisement

U s i n g t h e S e t b a c k Fe a t u r e
( c o n t i n u e d )
4
Access Screen 27 and set the setback return temperature for the air
exiting the hopper. This screen shows the actual temperature meas-
ured at the hopper outlet and the setpoint temperature for the air at the
hopper outlet that will initiate the control to go into setback.
5
Access Screen 28 and set the setback temperature band. This
screen shows how much lower the hopper outlet temperature must
drop from the Setback Return Temperature setpoint (Screen 27) before
the dryer control should restore the original process setpoint.
S e t b a c k Fe a t u r e G u i d e l i n e s
Careful selection of setpoint values in these functions is necessary for the
setback to operate properly. The following table is only a guideline of
recommended settings for these setpoints. It will be necessary for each
customer to determine the best setpoints for their application based on
experience.
Normal
Setback Return Temp
Drying Temp
160° F {71° C}
120° F {49° C}
240° F {116 C}
135° F {57° C}
300° F {149° C}
160° F {71° C}
340° F {171° C}
180° F {82° C}
Setback Temp
Screen #27
(Process) Screen #26
150° F {66° C}
180° F {82° C}
200° F {93° C}
220° F {104° C}