Control Panel Components And Features - Intec ColorSplash CS4000 Installation And Setup Manual

Enhanced print production envelope feeder
Hide thumbs Also See for ColorSplash CS4000:
Table of Contents

Advertisement

1.2. Control Panel Components and Features

Timeout reset / Jog button*
Ready/Feed switch
*tIMEoUt FEatUrE
The colorSplash's EPP Envelope Feeder
features a timeout function. during
operation, if the optical sensor mounted at
the exit end of the acceleration table (the
STOP Envelope Sensor) does not detect
an envelope for 4 seconds, the feed motor
will be paused. This is to ensure that the
motor does not 'run on' in the event the
feeder runs out of envelopes, or a jam
occurs in the feeder.
The Reset / Jog button shown above is
used to reset the timer and allow the motor
to restart running after a timeout occurs.
If you press and hold this button in,
the motor will run continuously until an
envelope covers the optical stop sensor.
Speed adjust knob
24 Vdc power input jack
The variable speed control can be
adjusted to accommodate different size
envelopes. As a general rule, most small
envelopes will require approximately 50%
maximum speed or more. For envelopes
150mm (6" long) in the running direction or
longer, higher speeds will be required for
consistent operation.
The feeder utilizes a low voltage 24 Vdc\5
amp external power supply. An on board
5 amp fuse is included for electrical
component protection. This fuse can be
accessed by unscrewing the fuse cap in
the lower right corner of the control panel.
4
Mains power switch
Fuse holder (5 amp fuse)