ELEcTrIcAL cONNEcTION
5 Electrical connection
DANGEr
NOTICE
5.1 connection of the brake
NOTICE
If no suitable DC voltage is available, the following KEB accessories can be used:
•
•
The brake COMBISTOP Type 38 is delivered with factory-preassembled connecting
cables:
cOMbISTOP 38
Connection cross
section
Connection length
Table 8:
Electrical voltage at brake and motor!
Danger to life due to electric shock!
► When carrying out any work on the brake, switch off the supply volt-
age and secure it against switching on.
Voltage peaks when switching off!
► Install protective circuit for brake and control.
► The protective circuit extends the engaging times.
Destruction of the brake in case of incorrect voltage supply.
► The brake is operated with DC voltage.
► Read the rated voltage from the magnet marking of the brake.
► Compare with existing voltage source.
► The maximum input voltage U
► Only connect if the values match.
Half and full-wave rectifier (COMBITRON 91)
Fast acting rectifier (COMBITRON 98)
2 x 0.75 mm²
500 mm + 100 mm
Pre-assembled connection cables
must not be exceeded.
in
02...06
07...10
2 x 0.75 mm²
750 mm + 100 mm
11
2 x 0.75 mm²
1000 mm + 100 mm
35