Programming dc power supply

Advertisement

Programming Manual
":SYSTem:COMMunicate:LAN:APPLy". Otherwise, the result queried by this command is the currently
operating parameter of the device.
It returns:"255.255.255.0" .
For Example::SYSTem:COMMunicate:LAN:SMASK?
Return:"255.255.255.0"
:SYSTem:COMMunicate:LAN:GATEway
Format::SYSTem:COMMunicate:LAN:GATEway "x.x.x.x"
Function:Set the network gateway of the device.
Description:When use this command to set the network parameter, the setup parameter will not take effect
immediately and will not save to nonvolatile memory of the device. It must execute the command
":SYSTem:COMMunicate:LAN:APPLy"to make the parameter validly and save permanently. You can
execute multiple commands to modify multiple parameters and then execute a single
":SYSTem:COMMunicate:LAN:APPLy" command together.
For Example::SYSTem:COMMunicate:LAN:GATEway "192.168.10.1"
Set the network gateway to 192.168.10.1
:SYSTem:COMMunicate:LAN:APPLy
set.
:SYSTem:COMMunicate:LAN:GATEway?
Format::SYSTem:COMMunicate:LAN:GATEway?
Function:Query the network gateway of the device.
Description:After the network parameter is set and before executing the
command":SYSTem:COMMunicate:LAN:APPLy", the result queried by this command is the temporary
parameter and it reflects the parameter data used when executing the command
":SYSTem:COMMunicate:LAN:APPLy". Otherwise, the result queried by this command is the currently
operating parameter of the device.
It returns:"192.168.10.1" .
For Example::SYSTem:COMMunicate:LAN:GATEway?
Return:"192.168.10.1"
:SYSTem:COMMunicate:RS232:BAUD
Format::SYSTem:COMMunicate:RS232:BAUD {4800|7200|9600|14400|19200|38400|57600|115200|128000}
Function:Set the baud rate for RS232 interface.
For Example::SYSTem:COMMunicate:RS232:BAUD 9600 Set the baud rate of RS232 to 9600.
:SYSTem:COMMunicate:RS232:BAUD?
Format::SYSTem:COMMunicate:RS232:BAUD?
Function:Query the baud rate of RS232 interface.
Description:It returns"{4800|7200|9600|14400|19200|38400|57600|115200|128000} ".