Download Print this page

UNI-T UDP3000S Series Programming Manual page 28

Programming dc power supply

Advertisement

Programming Manual
Function:Set the stop condition of delayer for the current channel.
Description:When the delayer is running and meet the stop condition, the delayer will stop automatically. When
<value> parameter is ignored, it only set the judgement condition, not change the original judgement value.
Notice:When the delayer is running, the parameter can not be set.
For Example::DELAY:STOP >V, 10.00
:DELAY:STOP?
Format::DELAY:STOP?
Function:Query the stop condition of delayer for the current channel.
Description:It returns" (NONE|<V|>V|<C|>C|<P|>P [,<value>])", if the first return parameter is "NONE", it will not
have the second parameter.
For Example::DELAY:STOP?
Return:>V,10.000
:DELAY:PARAmeter
Format::DELAY:PARAmeter <index>, {ON|OFF}, <time>
Function:Set the group parameter of delayer for the current channel.
Description:index:group serial number of the group that need to be set, range: 0-2047.
ON|OFF: Output status of the group.
time:Running time of the group, the unit is second.
Notice:When the delayer is running, the parameter can not be set.
For Example::DELAY:PARAmeter 0, ON, 10
:DELAY:PARAmeter?
Format::DELAY:PARAmeter? <index> [,<count>]
Function:Query the group parameter of delayer for the current channel.
Description:index:Query the setting parameter start from the serial number of the group,range: 0-2047.
count:Number of group that need to be queried,range: 1-10. When the parameter is ignored, query 1 group
by default.
Return Format:It returns data by data block, data field is serial number, output switch status and time of each
group. Such as "#190,ON,1.0;", #19 represents data field have 19 data ——"0,ON,1.0;",data contents shows
group number 0, the output is enabled, time is 1.0s.
For Example::DELAY:PARAmeter? 0
Return:#190,ON,1.0;
:DELAY:GENerate:STAT
Format::DELAY:GENerate:STAT < index>, <point>, {01P|10P}
Function:The group parameters of the delayer are automatically generated according to the state generation
mode.
Instruments.uni-trend.com
UDP3000S Series
28 / 49

Advertisement

loading

This manual is also suitable for:

Udp3305s