Download Print this page

UNI-T UDP3000S Series Programming Manual page 37

Programming dc power supply

Advertisement

Programming Manual
AUTO:Automatic trigger, the instrument can always generate the trigger condition at this time; it cannot have
parameter with<value>;
OUTOFF:It will generate the trigger condition when the controlled source turn off the ouput; It cannot have
parameter with<value>;
OUTON:It will generate the trigger condition when the controlled source turn on the ouput;It cannot have
parameter with<value>;
>V:It will generate the trigger condition when the voltage of the controller source is greater than the
judgement value; The parameter <value> cannot be omitted;
<V:It will generate the trigger condition when the voltage of the controller source is less than the judgement
value; The parameter <value> cannot be omitted;
=V:It will generate the trigger condition when the voltage of the controller source is equal to the judgement
value;The parameter <value> cannot be omitted;
>C:It will generate the trigger condition when the current of the controller source is greater than the judgement
value;
The parameter <value> cannot be omitted;
<C:It will generate the trigger condition when the current of the controller source is greater than the judgement
value;
The parameter <value> cannot be omitted;
=C:It will generate the trigger condition when the current of the controller source is equal to the judgement
value;
The parameter <value> cannot be omitted;
>P:It will generate the trigger condition when the power of the controller source is greater than the judgement
value;
The parameter <value> cannot be omitted;
<P:It will generate the trigger condition when the power of the controller source is less than the judgement
value; The parameter <value> cannot be omitted;
=P:It will generate the trigger condition when the power of the controller source is equal to the judgement
value;The parameter <value> cannot be omitted.
For Example::TRIGger:OUT:CONDition D0,>V,30.00 Set the trigger condition of IO1 to the voltage is greater
than 30.00 volts.
:TRIGger:OUT:CONDition
Format::TRIGger:OUT:CONDition {D0|D1|D2|D3}
Function:Query the trigger condition of output mode trigger.
Description:D0|D1|D2|D3:Select output IO,D0-IO1,D1-IO2,D2-IO3,D3-IO4.
Return:"{AUTO|OUTOFF|OUTON|>V|<V|=V|>C|<C|=C|>P|<P|=P} [,<value>]"。
Return"AUTO|OUTOFF|OUTON", it cannot have parameter with<value>;
Return">V|<V|=V|>C|<C|=C|>P|<P|=P", it have parameter<value>.
For Example::TRIGger:OUT:CONDition? D0
Return:>V,30.00
30.00 volts.
:TRIGger:OUT:POLArity
Format::TRIGger:OUT:POLArity {D0|D1|D2|D3},{POSItive|NEGAtive}
Instruments.uni-trend.com
Query the output trigger condition of IO1.
Return result:trigger condition is voltage is greater than
UDP3000S Series