Summary of Contents for UNI-T UTP3300C Series

  • Page 2: Safety Overview

    UTP3000C Series User Manual Safety Overview This section discusses the UTP3000C series safety instructions and storage conditions. Please read the information below carefully before using the device. Safety Symbols These symbols will be presented in the manual or the device. Caution Risk of Electric Shock Ground Terminal...
  • Page 3: Main Features

    UTP3000C Series User Manual Profile UTP3000C Series Programmable DC Power Suppliesare high precision 4-bit display devices with 3-way output. It is built with voltage and current overload protection, convenient operation panel,and one key storage recall. It can be used in aging test, electronics circuit behavior test, and automated system test of different environments.
  • Page 4 UTP3000C Series User Manual Function 1. Voltage and Current Settings and Output 1. Press , the displayed voltage of CH1 flashes, during which turn voltage adjustment knob to set the value; Press again to switch from voltage to current, during which turn current adjustment knob to set the value; keep pressingto switch between voltage and current.
  • Page 5 UTP3000C Series User Manual 2. Series and Parallel Settings Series settings: Press for 3s to enter into series mode and SER light will be on. Then CH1 operation is shielded, and CH2 will actas the main control; Press to enable/disable output.The connection method of series terminal is as below, 2.
  • Page 6 UTP3000C Series User Manual 5. Over Voltage Protection Setting Press for 3s to enter into Over Voltage Protection (OVP) setting and OVP SET light willflash; Press CH1/2 to select the channel, and turn voltage adjustment knob to adjust value; Press again for 3s, the device exists setting and OVP light will be off.
  • Page 7 UTP3000C Series User Manual Remote Control COM setting: set computer COM portsetting as below: • Baud Rate: 9600 • Calibration Bit: None • Data Bit: 8 • Stop Bit: 1 RS232 Interface Definition Communication protocol V2.0 Order Format: VSET<X>:<NR2> 1. VSET: Order Parameter 2.
  • Page 8 2,3,4,5 Output 0=Off, 1=On 11. *IDN? Function Description: Return to device model & factory information Example: *IDN? Contents UNI-T P33XC V2.0 (manufacturer, model name) 12. RCL<NR1> Function Description:Storage recall by pressing keys from M1-M5 13. SAV<NR1> Function Description: Storage setting Example: SAV1 Stores the panel setting in memory number 1 14.
  • Page 9: Technical Index

    UTP3000C Series User Manual Function Description: Set series & parallel output NR1:0=independent output; 1=series output; 2=parallel output Example: TRACK1 15. OCP<Boolean> Function Description: Turn on over current protection Boolean: 0 OFF, 1 ON Example: OCP1 Turn on OCP 16. OVP<Boolean> Function Description: Turn on over voltage protection Boolean: 0 OFF, 1 ON Example: OVP1 Turn on OVP...
  • Page 10 UTP3000C Series User Manual Voltage 10mV 10mV Current Read-back Temperature Coefficient Voltage ≤150ppm ≤150ppm Current ≤150ppm ≤150ppm Voltage Rise Delay ≤100ms ≤100ms Voltage Rise Delay (10% Rated load) (10% Rated load) Parallel Load Effect Voltage ≤0.1%+0.1V Series Load Effect Voltage ≤0.1%+0.1V CH3 Output Parameter Voltage Range...

This manual is also suitable for:

Utp3305cUtp3303c

Table of Contents