:PRESet1:SET:OCP CH1, ON
:PRESet1:SET:OCP CH1, OFF, 2.000
:PRESet1:SET:OCP CH1, ON, 1.500
:PRESet#:SET:OCP?
Format::PRESet#:SET:OCP? {CH1|CH2|CH3|SER|PARA}
Function:Query the overcurrent protective switch and value of the preset group.
Description:The optional values for # are"1|2|3|4|5", cannot be omitted and the corresponding preset group. It
returns"{OFF|ON}, <value>".
OFF|ON:The switch status of overcurrent protective;
<value>:Real value, overcurrent protective value.
For Example::PRESet1:SET:OCP? CH1
Return:ON,1.500
12. Memory
:MEMory[:STATe]:STORe
Format::MEMory[:STATe]:STORe
Function:Save the setup data to the specified position in internal memory.
Description:"STA"is the setup data of normal mode.LST" is the setup data of list output. "DLY"is the setup data
of the delayer.
For Example::MEM:STOR STA, 1
:MEMory[:STATe]:LOAD
Format::MEMory[:STATe]:LOAD
Function:Loading the setup data of the specified position from the internal memory.
Description:"STA"is the setup data of normal mode."LST" is the setup data of list output."DLY"is the setup data
of the delayer.
For Example::MEM:LOAD STA, 1
:MEMory[:STATe]:DELete
Format::MEMory[:STATe]:DELete
Function:Delete the saved data of the specified position from the internal memory.
Description:"STA"is the setup data of normal mode."LST" is the setup data of list output."DLY"is the setup data
of the delayer."REC"is the record file.
For Example::MEM:DEL STA, 1
:MEMory[:STATe]:VALid?
Format::MEMory[:STATe]:VALid?
Function:Checke whether data is saved at the specified position internal memory.
Instruments.uni-trend.com
{STA|LST|DLY}, {1|2|3|4|5|6|7|8|9|10}
{STA|LST|DLY}, {1|2|3|4|5|6|7|8|9|10}
{STA|LST|DLY|REC}, {1|2|3|4|5|6|7|8|9|10}
{STA|LST|DLY|REC}, {1|2|3|4|5|6|7|8|9|10}. RETURN:(YES|NO)