:LISTout[:STATe]?
Format::LISTout[:STATe]?
Function:Query the list output status mode of the current channel.
Description:It returns"Status (ON|PAUSED|ERROR|OFF), remaining time, the current point, termination point,
remaining cycle count, stop status (OFF|LAST)".
For Example::LISTout[:STATe]?
Return:ON,1.0,7,2047,0,OFF
:LISTout:BASE
Format::LISTout:BASE <StrN>, <Grpn>, <CycN>, {OFF|LAST}
Function:Set the basic parameter for list output mode of the current channel.
Description:StrN:Output initial group number,range 0-2047,StrN + Grpn can not greater than 2048.
Grpn:Output group number,range 1-2048,StrN + Grpn can not greater than 2048.
CycN: Cycle count,range 1-99999.
OFF|LAST:Stop status, close output or keep the last output status.
Notice:When list output is running, the parameter can not be set.
For Example::LISTout:BASE 1,100,1,OFF
:LISTout:BASE?
Format::LISTout:BASE?
Function:Query the basic parameter of list output mode of the current channel.
Description:It returns"StrN, Grpn, CycN, {OFF|LAST}"
StrN:Output initial group number,range 0-2047.
Grpn:Output group number,range 1-2048.
CycN: Cycle count,range 1-99999.
OFF|LAST:Stop status, close output or keep the last output status.
For Example::LISTout:BASE?
Return:1,100,1,OFF
:LISTout:PARAmeter
Format::LISTout:PARAmeter <index>, <volt>, <curr>, <time>
Function:Set the group parameter for list output mode of the current channel.
Description:index:The group serial number for the group need to be set,range 0-2047.
volt:Output voltage of the group,unit is volt.
curr: Output current of the group,unit is ampere.
time:Output time of the group,unit is second.
Notice:When list output is running, the parameter can not be set.
For Example::LISTout:PARAmeter 0, 10.00, 3.00, 1.5
Instruments.uni-trend.com