Function:Query the actual voltage, current and power value at the output terminal of the specified channel.
Description:If the channel parameter is ignored, then the current channel which is the channel need to be
queried by default.
For Example::MEASure:ALL? CH1
Return:05.10,0.089,00.45
:MEASure[:VOLTage][:DC]?
Format::MEASure[:VOLTage][:DC]? [CH1|CH2|CH3|SER|PARA]
Function:Query the actual voltage value at the output terminal of the specified channel.
Description:If the channel parameter is ignored, then the current channel which is the channel need to be
queried by default.
For Example::MEASure:VOLTage? CH1
Return:05.10
:MEASure:CURRent[:DC]?
Format::MEASure:CURRent[:DC]? [CH1|CH2|CH3|SER|PARA]
Function:Query the actual current value at the output terminal of the specified channel.
Description:If the channel parameter is ignored, then the current channel which is the channel need to be
queried by default.
For Example::MEASure:CURRent? CH1
Return:0.089
:MEASure:POWEr[:DC]?
Format::MEASure:POWEr[:DC]? [CH1|CH2|CH3|SER|PARA]
Function:Query the actual power value at the output terminal of the specified channel.
Description:If the channel parameter is ignored, then the current channel which is the channel need to be
queried by default.
For Example::MEASure:POWEr? CH1
Return:00.45
7. LISTout
:LISTout[:STATe]
Format::LISTout[:STATe] {0|1|OFF|ON}
Function:Start or stop the list output mode of the current channel.
Description:It can set and query the current channel by the command in"INSTrument"chapter.
For Example::LISTout:STATe ON