The printer will then automatically build an XY
Calibration part (approximately 10 minutes). You must
inspect the XY Calibration part and calibrate the X and
Y axes for tip offset. See paragraphs 1 through 4 on
page 56.
Prepare Printer for Return to Service
1. Install plastic head cover.
2. Exit Maintenance - press Next > then Done.
3. Unload the material. Make sure that the cartridges are entirely
removed so that all of the filament loaded into the printer can
be withdrawn. (See
It is recommended that an unload be performed for each
material.
4. Load material (See

Clogged Liquefier Tip

Occasionally, a Liquefier Tip may clog with material. This is often
accompanied by a Loss of Extrusion (LOE). (Refer to
Extrusion" on page

Clearing A Clogged Liquefier Tip

It is recommended that you read and understand this entire
procedure before performing any of the work.
This procedure assumes that filament is loaded to near the
liquefier tip. If filament has not been loaded,
Material" on page 32.
"Unloading Material" on page
NOTE
"Loading Material" on page 32.
63.). A clogged Tip will prohibit material load.
NOTE
Dimension BST 1200es / SST 1200es User Guide
Troubleshooting 69
36..
"Loss of
see
"Loading