Fault Determination Codes; Loss Of Extrusion; Diagnosing Loss Of Extrusion - µ-Dimension SST 1200es User Manual

Hide thumbs Also See for SST 1200es:
Table of Contents

Advertisement

Fault Determination Codes

If a fault occurs, which would prevent Dimension from executing an
operator request, the system will begin to shut down and cool. The
panel will display one or two error codes. An error-code list (with
the filename "error.txt") can be found on the CD-ROM for the
controller software. (Because this list may change with each new
software version, be sure to check the error.txt attachment when
you download new software upgrades.)
After the printer has finished cooling, the only option displayed is
Continue. Press Continue and the printer reboots and tries to
return to normal operation. If pressing Continue does not recover
the printer, the printer should be power cycled (see
on page
31.); wait 60 seconds before switching power on again. In
most cases you will be able to continue operation. However, if the
printer continues to shut down and display the same error, call your
service representative.

Loss of Extrusion

Diagnosing Loss of Extrusion

Occasionally, the printer's head may experience loss of extrusion.
This will be evident by observing one of the following:
Seeing the head moving with no material coming out of
either liquefier tip
The height of the model and support materials are not
equal
Sagging structures due to lack of support materials
Diagnose loss of extrusion:
1. Press Cancel and remove any parts from the printer.
WARNING
The head area is very hot!! Use gloves
when working in this area of printer!
Dimension BST 1200es / SST 1200es User Guide
Troubleshooting 63
"Cycling Power"

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Bst 1200es

Table of Contents