Operations Of Remote Control Units In Promig 501 And 511 Wire Feed Units - Kemppi PROMIG 511 Operation Instructions Manual

Hide thumbs Also See for PROMIG 511:
Table of Contents

Advertisement

4.
OPERATIONS OF REMOTE CONTROL UNITS
IN PROMIG 501 AND 511 WIRE FEED UNITS
R20
R63
R63
MIG
Setting for wire feed:
I 1...18 m/min
II 1...25 m/min
SELECTO
Channel selection: 1...5 corresponding
to settings 1, 4, 6, 8, 10 of knob
SYNERGIC MIG
Setting for power (wire feed speed):
according to wire min. ... max.
SYNERGIC
Setting for power (wire feed speed):
PULSED MIG
according to wire min. ... max.
Fine adjustment for arc length: 1...10
MMA
Setting for power:
10 A ... max. power of power source
R10, RMT10
R61
MIG
Setting for wire feed:
I 1...18 m/min
II 1...25 m/min
SELECTO
Channel selection: 1...5 corresponds in the R10 settings
1, 4, 6, 8, 10 of knob
SYNERGIC MIG
Setting for power (wire feed speed): according to wire min. ... max.
SYNERGIC
Setting for power (wire feed speed):
PULSED MIG
according to wire min. ... max.
MMA
Setting for power:
10 A...max.power of power source
© KEMPPI OY
R61
R61
Setting for voltage:
10 V...max. voltage of power source
(35...46 V)
Fine adjustment for arc length:
1...10
Fine adjustment for arc length:
1...10
NO OPERATION
R61
NOTE ! RMT10
NO OPERATION
PROMIG 501, PROMIG 511/0537 – 27

Advertisement

Table of Contents
loading

This manual is also suitable for:

Promig 501Promig 501l

Table of Contents