Operations Of Remote Control Units; Disposal Of The Machine - Kemppi Promig 100 Operation Instructions Manual

Table of Contents

Advertisement

Available languages

Available languages

4.

OPERATIONS OF REMOTE CONTROL UNITS

R63
R20
MIG
R63 Setting for wire feed: I 1...18m/min, II 1...25m/min
R61 Setting for voltage: 10 V...max. voltage of power source (35...45V)
Selecto
R63 Channel selection: 1...5 corresponding to settings 1, 4, 6, 8, 10 of knob
R61 Fine adjustment for arc length: 1...10
Synergic MIG
R63 Setting for power (wire feed speed): according to wire min. ... max.
R61 Fine adjustment for arc length: 1...10
Synergic PULSMIG
R63 Setting for power (wire feed speed): according to wire min. ... .max.
R61 Fine adjustment for arc length: 1...10
MMA
R63 Setting for power: 10 A...max. power of power source
R61 NO OPERATION
R10
MIG
R61 Setting for wire feed: I 1...18m/min, II 1...25m/min
Selecto
R61 Channel selection: 1...5 corresponds in the R10 settings 1, 4, 6, 8, 10 of knob
Synergic MIG
R61 Setting for power (wire feed speed): according to wire min .... max.
Synergic PULSMIG
R61 Setting for power (wire feed speed): according to wire min. ... max.
MMA
R61 Setting for power: 10 A...max.power of power source

5. DISPOSAL OF THE MACHINE

Do not dispose of electrical equipment together with normal waste!
In observance of European Directive 2002/96/EC on Waste Electrical and Electronic Equipment and
its implementation in accordance with national law, electrical equipment that has reached the end of
its life must be collected separately and returned to an environmentally compatible recycling facility.
As the owner of the equipment, you should get information on approved collection systems from our
local representative.
By applying this European Directive you will improve the environment and human health!
16 – Promig 100/0601
R61
RMT10
R61
©
KEMPPI OY

Advertisement