Remote Control Units; Installation Of Tig/Mma Equipment; Choice Of Electrode And Flow Amount Of Shielding Gas; Shielding Gas - Kemppi Protig 410 Operation Instructions Manual

Table of Contents

Advertisement

2.1.9. Remote control units

Connect remote control unit as shown in figures on page 4 or 5. Operation of remote control unit
is explained on page 19.
2.2.

INSTALLATION OF TIG/MMA EQUIPMENT

Fasten earthing press of ground cable carefully, preferably direct to welding piece. Contact
surface of press always should be as large as possible.
Clean the fastening surface from paint and rust!
Use in your TIG/MMA equipment 50 mm
overheating of connectors and insulations.
Make sure that the torch being in your use is designed for max. welding current needed by you!
Never use a damaged torch!
2.2.1. Choice of electrode and flow amount of shielding gas
Use argon as TIG shielding gas. Electrode size and shielding gas flow rate are defined by wel-
ding current size. The table below is given only as a guide.
Welding current
Electrode
A
ø mm
5...80
1,0
70...150
1,6
140...250
2,4
225...330
3,2
330...
4,0
2.3.
SHIELD GAS
Handle gas bottle with care. There is a risk for injury if gas bottle or bottle valve
is damaged!
For welding stainless steels, mixed gases are normally used. Check that the gas bottle valve
is suitable for the gas. The flow rate is set according to the welding power used in the job. A
suitable flow rate is normally 8 - 10 l/min. If the gas flow is not suitable, the welded joint will be
sporous. Contact your local Kemppi-dealer for choosing gas and equipment.

2.3.1. Installing gas bottle

Always fasten gas bottle properly in vertical position in a special holder on the
wall or on a carriage. Remember to close gas bottle valve after having finished
welding.
© KEMPPI OY
cables. Thinner cross-sectional areas might cause
2
Gas nozzle
number
ø mm
4 / 5
6,5 / 8,0
4 / 5 / 6
6,5 / 8,0 /9,5
6 / 7
9,5 / 11,0
7 / 8
11,0 / 12,5
10
16,0
Gas flow rate
l/min
5...6
6..7
7...8
8...10
10...12
PROTIG 410 / 0537 – 9