Changing The Flat Jet Nozzle; Removing The Flat Jet Nozzle - WAGNER PEM-X1 CG Translation Of The Original Operating Manual

Powder cup gun
Hide thumbs Also See for PEM-X1 CG:
Table of Contents

Advertisement

Operating manual Powder Cup Gun PEM-X1 CG
8   Cleaning and Maintenance
8.4   CHANGING THE FLAT JET NOZZLE
8.4.1   Removing the Flat Jet Nozzle
1.
3.
P_04982
1. Unscrew the union nut from gun housing.
2. Remove the union nut with the nozzle system from the gun body.
The nozzle system remains inserted in the union nut.
Note:
If the nozzle system doesn't remain inserted in the union nut, the nozzle system and
union nut must be replaced.
3. The parts can be separated by applying slight pressure to the flat jet nozzle.
4. Remove powder residues from the removed parts and spray gun.
Note:
Never place spray gun, or parts of it, in cleaning agent.
As a rule, the protective wedge needs to be checked for wear and replaced if necessary.
Order number 2326960 | Edition 10/2022
2.
33

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pem-x1

Table of Contents