Operating manual Powder Cup Gun PEM-X1 CG
8   Cleaning and Maintenance
8.5   CHANGING THE ROUND JET NOZZLE
8.5.1   Removing the Round Jet Nozzle
1.
1. Pull off deflector cone.
2. Unscrew the union nut from gun housing.
3. Remove the union nut with the nozzle system from the gun body.
The nozzle system remains inserted in the union nut.
Note:
If the nozzle system doesn't remain inserted in the union nut, the nozzle system and
union nut must be replaced.
4. Press nozzle system out of union nut by gently pressing on deflector cone sleeve.
5. Remove powder residues from the removed parts and spray gun.
Note:
Never place spray gun, or parts of it, in cleaning agent.
As a rule, the protective wedge needs to be checked for wear and replaced if necessary.
Order number 2326960 | Edition 10/2022
2.
3.
P_01677
4.
35